On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.
You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP are the wires going to the Alarm, opened or closed?
Alarm is an OUTPUT. The contact closes when the lock goes into full alarm.
When lock is not in alarm, the contacts are open
...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M450P, does this indicator light come with the lock?
No, it is in a kit sold separately (ATS/LED kit) and the lock must be a Plus "P" version to use this kit. This can be ordered separate and installed in the field....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What size screws are used with the M490 mag locks?
Inside mounting bracket screws are USS 10-24 x 1/2"
Outside mounting bracket screws are USS 10-32 X 3/4"
Magnet Screws - Are 1/4 - 20 thread 3/16 hex total length 2 ¾
Cover Plate Screw ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics