What are the weight differences for the M400 series Mag Locks?
M420 - 6 lbs M450 - 10 lbs M490 - 14 lbs...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
On the M400P series maglock, is the ATS/MBS LED red?
LED is green....
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
Does M490P and M490 armature housing comes with the 2 magnets on the corners?
The M490P has magnets on the housing but the M490 does not. When you order as a separate part you get the armature and housing for the M490P since it will work in both applications. But if they are re...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.  ​You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Why does the M490DE/DEP delay for a few second before releasing after the 15 seconds egress?
Check the Armature, it may be on backwards....
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP are the wires going to the Alarm, opened or closed?
Alarm is an OUTPUT.  The contact closes when the lock goes into full alarm. ​When lock is not in alarm, the contacts are open ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
How do you wire up an M490DE to a 900-4RL with a FA on it so it will drop power in a fire alarm condition?
Any powered outputs on the 900-4RL will lose power if the FA board on the 900-4RL opens, use a dry relay to trigger release input, the Maglock should be on NO1 and C1 and a jumper on I1 and SC. ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M450P, does this indicator light come with the lock?
No, it is in a kit sold separately (ATS/LED kit) and the lock must be a Plus "P" version to use this kit.  This can be ordered separate and installed in the field....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What size screws are used with the M490 mag locks?
Inside mounting bracket screws are USS 10-24 x 1/2" Outside mounting bracket screws are USS 10-32 X 3/4" Magnet Screws - Are 1/4 - 20 thread 3/16 hex total length 2 ¾ Cover Plate Screw ...
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What should the Ohms read on a coil in a M490G?
Approximately 30-40 Ohms (the one on our test bench measured at 32.8 Ohms on each coil)....
Schlage Commercial » System Components » Electromagnetic Locks » M400 Series