How is the QEL calibrated?
Calibration is an internal process of the QEL device when energized the 1st time.  The solenoid will pull and drop 3 times on a standard calibration.  Calibration can be forced by press...
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Power Supplies » Standard » PS900 Series » Von Duprin | System Components » Electrified System Component Accessories » Rectifier » Von Duprin | Von Duprin
Can you power an electric strike or maglock from the 9500 Series Senior Swing?
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Sen...
Automatic Operators » Electromechanical » Senior Swing » LCN | System Components » Electrified System Component Accessories » Rectifier » Von Duprin
Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid.  You must change to a 24V solenoid, part number 050240-00....