On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.  ​You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Why does the M490DE/DEP delays for a few second before releasing after the 15 seconds egress?
Check the Armature, it may be on backwards....
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP are the wires going to the Alarm, opened or closed?
Alarm is an OUTPUT.  The contact closes when the lock goes into full alarm. ​When lock is not in alarm, the contacts are open ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
How do you wire up an M490DE to a 900-4RL with a FA on it so it will drop power in a fire alarm condition?
Any powered outputs on the 900-4RL will lose power if the FA board on the 900-4RL opens, use a dry relay to trigger release input, the Maglock should be on NO1 and C1 and a jumper on I1 and SC....
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Does the M490DE come with a delayed egress warning sign?
A delayed egress sign is provided with the M490DE and the M490DEP.  The sign's part number is P774358...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Can I bypass the circuit board on a M420 M450 or M490: Unsupported voids warranty
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Why is my mag lock buzzing?
If a magnetic lock is buzzing or noisy it could be the result of an AC component riding on the DC supply voltage. Using a meter, check for AC riding the DC level. If possible test the mag lock with...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Maglock Making a "Buzzing" Noise
 AC-voltage or "noise" on a power line can cause hum. Ensure supply is filtered and regulated 12 or 24 volts.Not a transformer.Also ensure hardware is properly secure eliminating the possibl...
System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
M490 Armature only part number.
P23561707...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
M420 armature part number
P23566888...