Category: Power Supplies

(Results from 1 to 10)
What replaces the Von Duprin PS873 Power Supply
The PS900 series of power suppllies replace the PS873Only the PS900 series is UL294 compliant. PS873 is not UL294 compliant. ...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » Von Duprin
What is the finish on the PS914, PS906, PS904 or PS902 enclosure?
What are the finish and cabinet details on the PS914, PS906, PS904 or PS902 enclosure?Enclosure Details:Grey/baked enamel14" x 12" x 4" (H x W x D)Eight 1⁄2" x  3⁄4" knockoutsNEMA Grade 1Hing...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components | Schlage Commercial » Schlage Electronics
How do I program my device?
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature.  ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Biometrics | Schlage Commercial » Credentials | Schlage Commercial » Door Controls | Schlage Commercial » Doors and Frames | Schlage Commercial » Electronic Locks | Schlage Commercial » Exit Devices | Schlage Commercial » Key Systems | Schlage Commercial » Mechanical Accessories | Schlage Commercial » Mechanical Locks | Schlage Commercial » Power Supplies | Schlage Commercial » Readers | Schlage Commercial » Security Management | Schlage Commercial » Software | Schlage Commercial » System Components | Schlage Commercial » Falcon | Schlage Commercial » Glynn-Johnson | Schlage Commercial » Ives | Schlage Commercial » LCN | Schlage Commercial » Schlage | Schlage Commercial » Schlage Electronics | Schlage Commercial » Steelcraft | Schlage Commercial » Von Duprin
Is the 515 Legacy power supply field selectable between 12 and 24 volts?
No, the 515 was ordered as either 12 or 24 volts with no way to switch between like the newer PS-9xx versions....
Schlage Commercial » Power Supplies
What is the part number for the lock and key for PS9xx power supply enclosures?
900 KL...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard » PS900 Series
On the PS904 or PS906 Power Supply, can you mount the 900-FA board directly to the main board?
No, you will need a option board to mount the 900-FA.  The PS902 can support the 900-FA directly....
Schlage Commercial » Power Supplies
What are the Supervisor contacts used for on the PS 900series power supplies ?
The Supervision Input, which requires a normally-closed condition, can be used for supervising power sources   AC power – Green Led should be lit, also, there is a dry contact ( Supervisor ...
Schlage Commercial » Power Supplies
Can you use a PS902 with 900-2RS board to power an electric strike or is it for EL exit devices only?
The 900-2RS is typically only used for EL or QEL devices, even if a strike is fail secure the 900-4R or 900-4RL should be used. The 900-2RS output is a specific timed voltage output for EL and QEL so...
Schlage Commercial » Power Supplies
The Locknetics 592-24 RC transformers are phased out and there are no replacements. Is there an exact replacement?
A full PS-902 would replace it. Would get 24 VDC, but is much larger physically....
Schlage Commercial » Power Supplies
On the PS902, are the fuse ceramic or glass?
Ceramic....
Schlage Commercial » Power Supplies