Category: Schlage Electronics

(Results from 1 to 10)
Does the M490DE come with a delayed egress warning sign?
A delayed egress sign is provided with the M490DE and the M490DEP.  The sign's part number is P774358...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Can I bypass the circuit board on a M420 M450 or M490: Unsupported voids warranty
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Why is my mag lock buzzing?
If a magnetic lock is buzzing or noisy it could be the result of an AC component riding on the DC supply voltage. Using a meter, check for AC riding the DC level. If possible test the mag lock with...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Maglock Making a "Buzzing" Noise
 AC-voltage or "noise" on a power line can cause hum. Ensure supply is filtered and regulated 12 or 24 volts.Not a transformer.Also ensure hardware is properly secure eliminating the possibl...
System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
M490 Armature only part number.
P23561707...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
M420 armature part number
P23566888...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Armature part number for a M490DE
P44487767...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Armature part number for a M450.
P44489318...
System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Will mag locks operate with voltage ranges between 12vdc and 24vdc?
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that volt...
System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.  ​You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics