Can the Von Duprin 5100 electric strike be used on a pair of doors?
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullio...
System Components » Electric Strikes » 5100 Series » Von Duprin
Does Von Duprin have a repair department?
Von Duprin and Falcon do not offer repair services for any of its exit devices....
Exit Devices » Cross Bar » 55 Series » Von Duprin | Exit Devices » Cross Bar » 88 Series » Von Duprin | Exit Devices » Touch Bar » 22 Series » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Power Supplies » Standard » PS900 Series » Von Duprin | System Components » Electric Strikes » 4000 Series » Von Duprin | System Components » Electric Strikes » 5100 Series » Von Duprin | System Components » Electric Strikes » 6000 Series » Von Duprin | System Components » Electric Strikes » 6300 Series » Von Duprin
Do we offer a weatherproof electric strike?
No, due to the gate and backbox not being able to be sealed to keep water out of the electric strike a weather proof version is not available....
System Components » Electric Strikes » 5100 Series » Von Duprin | System Components » Electric Strikes » 6000 Series » Von Duprin
Why is a 5100 electric strike clicking but not locking?
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS ther...
System Components » Electric Strikes » 5100 Series » Von Duprin
Can 5100 electric strikebe used on fire rated door?
The Von Duprin 5100 electric strike is not for fire rated applications....
System Components » Electric Strikes » 5100 Series » Von Duprin
Why won't the 5100 24v strike work on both a RH & LH door?
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 or ...
System Components » Electric Strikes » 5100 Series » Von Duprin
Can the 5100 electric strike be used with a mortise exit device?
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow met...
Mechanical Locks » Mortised » L9000 Series » Schlage | System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage