Can the Von Duprin 5100 electric strike be used on a pair of doors?
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullio...
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin
Does Von Duprin have a repair department?
Von Duprin and Falcon do not offer repair services for any of its exit devices....
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 4000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Can the 5100 electric strike be used with mortise locks?
...
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Do we offer a weatherproof electric strike?
No, due to the gate and backbox not being able to be sealed to keep water out of the electric strike a weather proof version is not available....
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Why is a 5100 electric strike clicking but not locking?
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS ther...
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin
Is the 5100 electric strike handed?
The 5100 electric strike is not handed....
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin
What template is used for the 5100 strike in a wood frame?
See attached  template, sheet 3 for the 5100 electric strike in a wood frame.5100 electric strike templates...
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin
What is the part number only for the Entry Buzzer on 6000 series electric strike?
50242-00 is the part number for entry buzzer on 6000 series electric strikes....
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Which electric strike would I use with an HL6?
You could use the HL6 Hospital Latch with any electric strike that would work with a cylinderical latch such as the 5100, 6211, etc....
Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
Is the 5100 shipped FS or FSE?
5100 electric strike is shipped as a FSE - fail secure from the factory....