Category: MTSeries

(Results from 11 to 20)
Do all of the Allegion readers use RFID (radio Frequency Identification)?
Yes, and they are also ISO14443 standard compliant....
Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Why is my access control not seeing the read from my card on a OSDP connection?
We don't use secure OSDP, the controller will need to be set to open and then they should be able to see the data. ...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Do the new MTB readers have to be order as 485 to have this connection?
All MTB readers now include a 485 and wiegand connections.You do not have to specify 485 when ordering....
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Schlage MTKB - Keypad Output Configuration
The MTKB readers use the same keypad configuration as the MTK readers. Please see configuration manual here. ...
Schlage Commercial » Readers » Multi-Technology » MTSeries
What is the voltage range for the MTB readers?
The voltage range for the MTB / MTKB readers have been updated from 5v -16v to 5v - 28v. ...
Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Can the MT11/MT15 Wiegand readers be configured in the field to be 485?
No, the readers are not configurable in the field.  They need to be purchased as RS485 reader The new MTB11/MTB15 readers have wiegand and 485 enabled by default. ...
Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
MT20w Card reader was deleted and now it will not show up in "In range" devices to set up.
When any device is deleted from an Engage site, it will also need to be Factory Defaulted (Reset) before it can be commissioned back into Engage.If you are using the MT20W Enrollment Reader, there sho...
Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Electronic Locks » ENGAGE Application | Schlage Commercial » Electronic Locks » ENGAGE Application » Mobile App | Schlage Commercial » Readers » Enrollment » MT20W
PIV Credentials - CSN/UID
PIV cards have a 7 byte (56bit) CSN...
Schlage Commercial » Credentials » Smart Card | Schlage Commercial » Readers » Multi-Technology » MTSeries
Schlage MT20 Enrollment Reader - Enrolling 3rd Party Smart Cards via CSN
To configure an MT20 to enroll 3rd party smart cards via CSN: Use configuration card, part number CE-404-033, "Enable CSN".  The MT20 can then be used to enroll 3rd party smart credentials....
Schlage Commercial » Readers » Multi-Technology » MTSeries
Schlage Engage Readers and Locks - Enrolling iClass CSN
iClass cards read differently on CTE and NDE.   NDE readers can only see a truncated 40-bit iClass CSN CTE's MT11 and MT15 readers see a 64-bit iClass CSN, by default. C...
Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » CTE