Category: Schlage Electronics

(Results from 1 to 10)
What are the model numbers for the new Schlage and XceedID wall mounted credential readers?
  The Legacy wall mounted readers are replaced as shown in the table below:  The MTMS15 and MTMSK15 did not have any prior models that it replaced....
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Proximity » PR 10 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics
What is the read range of the Schlage MT11 wall mounted reader?
All read ranges are affected by the environment the reader and card are subjected too.  The following data was obtained in a relatively "noisy" RF area with the reader mounted on a metal bac...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Smart Card » XceedID Legacy Readers » Schlage Electronics
What is the read range of the new Schlage MT11 wall mounted reader?
All read ranges are affected by the environment the reader and card are subjected too.  The following data was obtained in a relatively "noisy" RF area with the reader mounted on a metal bac...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Smart Card » XceedID Legacy Readers » Schlage Electronics
Do Schlage readers require an Access Control Panel?
Yes, Schlage readers are pass-through devices, therefore, they require an Access Control Panel.  ...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Multi-Technology » XceedID Legacy Readers » Schlage Electronics | Schlage Commercial » Readers » OEM Module » OEM100 » Schlage Electronics | Schlage Commercial » Readers » Proximity » PR 10 » Schlage Electronics | Schlage Commercial » Readers » Proximity » XceedID Legacy Readers » Schlage Electronics | Schlage Commercial » Readers » Smart Card » Enrollment » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » XceedID Legacy Readers » Schlage Electronics
What are the differences between ISO 14443 and ISO 15693 smart card technologies?
The following list summerizes the main differences:  ...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Multi-Technology » XceedID Legacy Readers » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » XceedID Legacy Readers » Schlage Electronics
Are Schlage wall mounted readers FIPS 201 compliant?
The Schlage Smart and Multi-Technology Readers by Allegion have been approved by the U.S. Government under HSPD-12 for FIPS 201-1 compliance as PIV Transparent Readers. ...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Are all Smart Cards contactless?
Smart cards can come in two forms: contact and contactless. Contact smart cards operate much like magnetic stripe cards (credit cards, etc.), requiring insertion into or direct contact with a reader...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » Multi-Technology » XceedID Legacy Readers » Schlage Electronics | Schlage Commercial » Readers » Proximity » PR 10 » Schlage Electronics | Schlage Commercial » Readers » Proximity » XceedID Legacy Readers » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » XceedID Legacy Readers » Schlage Electronics
What is FIPS-201-2 compliant? How is it different than FIP-201-1?
The FIPS 201-1 standard has been replaced by FIPS 201-2. The new standard no longer defines specific credentials, readers or locks as compliant. Instead, only complete solutions developed through Phys...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
What is the default CSN output for Mifare Classic, Mifare Desfire EV1, and HID iClass?
The MiFare Classic CSN is 32-bits.The MiFare Desfire EV1 CSN is 56-bits.  We technically can read and report up to 64-bits if needed via a configuration card.The HID iClass CS...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » OEM Module » OEM100 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics
On the the Schlage reader data sheet, for Current Requirement, it says at 12 VDC and 25 C. What is the 25 C in this context?
When the current is tested on a reader, it’s tested using a constant power supply (12VDC) at a constant temperature of 25C or 77F.  From these tests, you get the average and peak mA that was me...
Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics | Schlage Commercial » Readers » OEM Module » OEM100 » Schlage Electronics | Schlage Commercial » Readers » Proximity » PR 10 » Schlage Electronics | Schlage Commercial » Readers » Smart Card » SM 10 » Schlage Electronics