Category: MTSeries

(Results from 1 to 10)
Can I flush mount Schlage MT series card readers?
The reader has curved edges, so it cannot be flush mounted....
Readers | Readers » Multi-Technology | Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
MT20w and Schlage Mifare Plus Credentials
No.  The MT20w only currently supports Schlage Mifare Classic and EV1 credentials....
Readers » Multi-Technology » MTSeries | Readers » Enrollment » MT20W
Schlage MT15 and MTK15 Readers - 5-Pin Port near Pigtail Connector
This is a connector port used to connect a mag-stripe reader to main body of reader.  This is used by MTMS15 and MTMSK15 reader configurations....
Readers » Multi-Technology » MTSeries
Using a MTK-15 with an 8 bit burst, do you have to press “#” when done putting in your access code?
This depends on the Access Control Panel, the reader is sending data with every press, so it's up to the Access Control Panel whether it needs the “#” or not....
Readers » Multi-Technology | Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
Do all of the Allegion readers use RFID (radio Frequency Identification)?
Yes, and they are also ISO14443 standard compliant....
Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
Why is my access control not seeing the read from my card on a OSDP connection?
We don't use secure OSDP, the controller will need to be set to open and then they should be able to see the data. ...
Readers » Multi-Technology | Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
Do the new MTB readers have to be order as 485 to have this connection?
All MTB readers now include a 485 and wiegand connections....
Readers » Multi-Technology | Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
Schlage MTKB - Keypad Output Configuration
The MTKB readers use the same keypad configuration as the MTK readers. Please see configuration manual here. ...
Readers » Multi-Technology » MTSeries
What is the voltage range for the MTB readers?
The voltage range for the MTB / MTKB readers have been updated from 5v -16v to 5v - 28v. ...
Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics
Can the MT11/MT15 Wiegand readers be configured in the field to be 485?
No, the readers are not configurable in the field.  They need to be purchased as RS485 reader The new MTB11/MTB15 readers have wiegand and 485 enabled by default. ...
Readers » Multi-Technology » MTSeries | Readers » Multi-Technology » MTSeries » Schlage Electronics