Will an AD Series lock retain reader settings if the reader module is replaced with one of the same type?
Yes, be sure to press the “S1” switch on the main board after installing the new reader so it will be recognized....
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
I added a 3’rd PIM -485 but my credentials are not working
·         Make sure the addressing is unique and not conflicting with assigned addresses for locks connected  PIM1 and PIM 2 ...
Schlage Commercial » Electronic Locks
For an AD-400 with an Athens lever, what is the distance from the tip of the lever to the surface of the door?
It is approximately 2 ¼ inches.  Some door designs have raised panels and may need more clearance. The Tubular, Sparta, and Rhodes designs may not have enough distance to accommodate these app...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
How come the new HHserial -2Pin cable is not working on the new HHD?
The new HHD needs to have the latest software update 6.3.3.  Available on the Schlage Support site....
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Hand Held Devices | Schlage Commercial » Electronic Locks » Hand Held Devices » HHD
How do I enroll i-buttons into the CT5000 without using Schlage Express and the HHD
Devices needed : SRT-100 i-button reader and MTK15 reader   ·         You will need to connect the SRT-100 i- button reader and the MTK15 reader (config...
Schlage Commercial » Electronic Locks
What is the correct part number for a AD/CO lock with a JDYA7 cylinder
Price book shows for the AD/CO locks- part number 23929722 for CY and MS     Ad service manual shows the same   Co service manual shows – CY- 23...
Schlage Commercial » Electronic Locks
Can lithium batteries be used in any AD or CO series locks?
No - alkaline batteries only....
Schlage Commercial » Electronic Locks
Does Engage work with PIV cards
PIV is NOT supported by ENGAGE. The readers on the locks are not compatible with PIV credentials.         ...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » ENGAGE Application | Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » Gateway | Schlage Commercial | Schlage Commercial » Electronic Locks » LE Series
Can you use AD or CO locks on lead line doors?
Locks used for lead lined doors need to have a lead lining option in the lock which we do not offer for AD and CO locks. AD and CO locks can't be used on lead lined doors....
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Offline
What is the fire rating for the LE lock?
The LE / LEB locks are UL10C rated. That is a 3-hour fire rating ...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » LE Series