Category: Isonas

(Results from 41 to 50)
What server information should be in Engage for Isonas linked sites?
When using Engage with the Isonas software,  in the server information please use the following: cloud-iot.isonas.com ...
Schlage Commercial » Electronic Locks » ENGAGE Application | Schlage Commercial » Software » Isonas
Is Pure Access compatible with PIV type Government issued credentials?
You cannot use PIV/FIPS/TWIC with the Isonas Pure Access systems. They are not compatible. ...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » Pure Access Manager | Schlage Commercial » Software » Isonas » Pure Access Cloud
How do you check Isonas diodes ACC-Back EMF-DIODE for proper function?
The check diodes, set the multimeter to diode (  ->|- ) setting and connect red lead to a black wire and black lead to a red wire. The display should read around .5 volts for proper function. ...
Schlage Commercial » Software » Isonas
How many inputs does the Schlage RC reader controller have?
The Schlage RC controllers has 3 configurable inputs. Door position (DPS) Request to Exit (REX) Auxiliary (AUX) ...
Schlage Commercial » Readers | Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC Reader Controller
Where can I find the wiring diagrams for Schlage RC11/RC15/RCK15?
You can use the highly detailed RC-04 wiring diagrams from the site below. Schlage RC11/RC15/RCK15 pigtails use the same wire colors as RC-04 pigtails with one exception- REX (blue) and Door Positio...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC Reader Controller
What PoE mode is used on Isonas hardware?
For the Isonas hardware you can use A or B PoE, but default is mode A....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
Does integrator level web access need to be disabled at each subtenant individually for Pure Access RMR users?
If you disable an integrator level web access, you will have to go into each and every one of your subtenants and disable that users web access....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » Pure Access Cloud
How can I see events other than SysAdmin in Isonas widgets?
On the History Widget, there is a MORE FILTERS selection.  Click on MORE FILTERS and there will be a slider for Show System Administrator.  Turn that Off temporarily and it will not...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » Pure Access Cloud
How many entries are displayed on the Isonas Dashboard on the History widget?
A maximum of 50 events are displayed on the history widget. If you need to see more, you can run a Report to see entries prior to those 50. ...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » Pure Access Cloud
What is the read range of the RC04?
The read range is typically 2 to 5 inches....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04