How many schedules can be assigned to one IP Bridge?
You can assign up to 29 schedules on an IP Bridge. ...
Schlage Commercial » Software » Isonas » IPBridge
Where can I find the Installation Guide for the Isonas IP-Bridge 2.0?
Please click here to download the IP-Bridge 2.0 installation guide. ...
Schlage Commercial » Software » Isonas » IPBridge
How to perform a factory default reset an Isonas IP-Bridge 2.0?
The Isonas IP-Bridgev2 has a recessed reset-button located in the position shown: There ae two reset operations available.: - Reset CPU: Press, hold (approx. 2 seconds) and release the ...
Schlage Commercial » Software » Isonas » IPBridge
What is the max cable run recommended for the RC04?
The ISONAS RC04, RC03, IPBridge can be powered via PoE on cable runs up to 100 meters long (the standard Ethernet cable limit). For device locations that have longer cable runs (> 5...
Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge
What is the current draw for IP Bridge?
IP Bridge Current Draw: 0.26 AMPS @ 12VDC 0.18 AMPS @ 24VDC PoE: 4 Watts ...
Schlage Commercial » Software » Isonas » IPBridge
What is the part number for the cable to power the IP Bridge thru external power supply?
Here is the part number for the external power cable: IPB-Cbl-Pwr1-3ft - 3 foot power cable with “1” connector for connecting external power. ...
Schlage Commercial » Readers » IP Based » Bridges and accessories (ASM/EDK) | Schlage Commercial » Software » Isonas » IPBridge
What PoE mode is used on Isonas hardware?
For the Isonas hardware you can use A or B PoE, but default is mode A....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
Can the IP Bridge be used outside?
No, the IP Bridge is indoor Use ONLY, -40° to +80° Celsius. ...
Schlage Commercial » Software » Isonas » IPBridge
Can an IP Bridge provide downstream POE power?
Yes it can.  Remove top cover and place jumper on pins 2 and 3 at JP1. ...
Schlage Commercial » Software » Isonas » IPBridge
What are the LED status indications on the IP Bridge?
IP-Bridge Status (Top of device) LED “A” LED “B” IP-Bridge is not powered on ...