Category: RC-04

(Results from 1 to 10)
Where can I find the wiring diagrams for Schlage RC11/RC15/RCK15?
You can use the highly detailed RC-04 wiring diagrams from the site below. Schlage RC11/RC15/RCK15 pigtails use the same wire colors as RC-04 pigtails with one exception- REX (blue) and Door Positio...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC Reader Controller
What is the max cable run recommended for the RC04?
The ISONAS RC04, RC03, IPBridge can be powered via PoE on cable runs up to 100 meters long (the standard Ethernet cable limit). For device locations that have longer cable runs (> 5...
Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge
What PoE mode is used on Isonas hardware?
For the Isonas hardware you can use A or B PoE, but default is mode A....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
What is the read range of the RC04?
The read range is typically 2 to 5 inches....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04
What is the weight of the RC04?
Mullion- 6.5 Oz Wall Mount- 8.0 Oz Wall Mount w/Keypad- 9.5 Oz. ...
Schlage Commercial » Software » Isonas » RC-04
Do they have to install the diode with the RC03 and the RC04?
The BackEMF diode that ships with Schlage and Isonas Reader-Controllers is required for low voltage DC installations with electric strikes. An industry standard 1N4007 diode can be used in its place.F...
Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03
Which diode can they use with the Isonas RC-04?
Isonas and Schlage Reader-Controller include a BackEMF diode that is often appropriate for an electric strike in a low voltage DC application. If the included BackEMF diode is no longer available an i...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Software » Isonas » RC-04
Isonas - Devices and Important Network Ports
Network configuration needed for Isonas-brand devices to connect to Isonas Pure Access CloudPort 55533 open on firewall10 Mbps, Full Duplex.  Auto-negotiate disabled.Ports used for the Isonas Con...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge
Isonas Devices, Schlage RC, and 802.1x Compliance
Isonas devices to not and cannot support 802.1xSchlage RC do not currently support 802.1x Note: Schlage NDE, NDEB, and LEB do support 802.1x, as the devices can save network authentication data....
Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » LE Series | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge | Schlage Commercial » Software » Isonas » RC Reader Controller
What is the size of the RC04?
Mullion - 5.10 x 1.70 x 0.71Wall Mount - 5.10 x 3.25 x 0.71Wall Mount w/Keypad - 5.10 x 3.25 x 0.75...
Schlage Commercial » Software » Isonas » RC-04