How do I set the relay time delay on the Locknetics WS200?
All jumpers installed will give you 0.5 secondsJumpers 3 & 4 installed will give you 5 secondsJumpers 1 & 2 installed will give you 10 secondsAll jumpers off will give you 20 seconds...
Schlage Commercial » System Components | Schlage Commercial » System Components » Electromagnetic Locks
Schlage M420, M450, M490 - Armature Bolt Replacement
The armature bolt is not available on its own, but it is included in the armature mounting fastener pack, part#
P44489128 for M450/M420
P44497110 for M490
...
Schlage Commercial » System Components » Electromagnetic Locks
Installing Electromagnetic Locks on Surface Vertical Rod Doors
It can be installed frame side of the rods, if there is room for it on the door.
Note: The holding force will be reduced when the maglock is not installed as close to the edge of the door as pos...
Schlage Commercial » System Components » Electromagnetic Locks
On the M450P, does this indicator light come with the lock?
No, it is in a kit sold separately (ATS/LED kit) and the lock must be a Plus "P" version to use this kit. This can be ordered separate and installed in the field....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
How do you use an auto operator with M490DE?
Yes, you can, but you will need a secondary relay that will trigger the release input prior to triggering the auto operator to open.
When using the Schlage PS900 series power supplies, you...
Schlage Commercial » System Components » Electromagnetic Locks