Category: Electromagnetic Locks

(Results from 41 to 50)
How do I set the relay time delay on the Locknetics WS200?
All jumpers installed will give you 0.5 secondsJumpers 3 & 4 installed will give you 5 secondsJumpers 1 & 2 installed will give you 10 secondsAll jumpers off will give you 20 seconds...
Schlage Commercial » System Components | Schlage Commercial » System Components » Electromagnetic Locks
Are the holes pre drilled on the 4904A angle brackets?
Only the mounting holes to mount it to the frame, the two holes offset slightly to upper edge....
Schlage Commercial » System Components | Schlage Commercial » System Components » Electromagnetic Locks
M400-Series Electromagnetic Lock - Cover Screw Size
US 8-32 X 1/4 Inch length Phillips head. The same size can be used for a Torx/Security screw. ...
Schlage Commercial » System Components » Electromagnetic Locks
Schlage M490DE Maglock - Can Delay Egress be Remotely Disabled
No, only via DIP switch 8 and/or the aux input. ...
Schlage Commercial » System Components » Electromagnetic Locks
Schlage M420, M450, M490 - Armature Bolt Replacement
The armature bolt is not available on its own, but it is included in the armature mounting fastener pack, part# P44489128 for M450/M420 P44497110 for M490 ...
Schlage Commercial » System Components » Electromagnetic Locks
Installing Electromagnetic Locks on Surface Vertical Rod Doors
It can be installed frame side of the rods, if there is room for it on the door. Note: The holding force will be reduced when the maglock is not installed as close to the edge of the door as pos...
Schlage Commercial » System Components » Electromagnetic Locks
On the M450P, does this indicator light come with the lock?
No, it is in a kit sold separately (ATS/LED kit) and the lock must be a Plus "P" version to use this kit.  This can be ordered separate and installed in the field....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Schlage M400-Series - HDB Kit Screw Sizes
(3) 10-32 x 3/8 set screws included with HDB brackets.  Applies to HDB420, HDB450, and HDB490 ...
Schlage Commercial » System Components » Electromagnetic Locks
Is there a maintenance recommendation for Schlage Electromagnetic Locks?
At twelve (12) monthly intervals the following maintenance should be followed; All fixing screws checked and tightened on the mag lock & armature plate. External surfaces wiped over...
Schlage Commercial » System Components » Electromagnetic Locks
How do you use an auto operator with M490DE?
Yes, you can, but you will need a secondary relay that will trigger the release input prior to triggering the auto operator to open.  When using the Schlage PS900 series power supplies, you...