Category: Electromagnetic Locks

(Results from 61 to 70)
Can I just swap out the PCB board in the M490DE and make it a M490DEP?
No, the MBS is in the coil assembly so switching out the PCB won't work....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
On a MG1200DT is the Door status sensor SPDT switch used to determine if door is open or closed like a DPS or MBS?
It works like a DPS, it is the same as a Door Position Switch....
Schlage Commercial » System Components | Schlage Commercial » System Components » Electromagnetic Locks
Are Torx security screws included in the M400 Series hardware packs?
Torx security screws are not included in the M400 Series hardware packs....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
Will a Herculite Door Bracket HDB work with a M490DE/DEP Mag Lock?
Yes, an HDB490 will work with a M490DE/DEP....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial
How do you troubleshoot the DPS on M490DEP Magnetic Locks?
Connect a meter set to ohms to the lead of the Door Position Switch (DPS) and look for a change of state when operating the lock....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
Why does the GF3000 Mag Lock temperature get so hot that it's burning to the touch, even with the use of the control module?
Using the wrong voltage or not using a class 2 regulated filtered power supply. It is recommended that the customer uses a SchlagePS900 Series Power supply for the best operatation....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial
How long is P44487825 M490 DEL 2 CABLE ASSY?
The length of the cable assembly is 48 inches....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
Does Schlage offer an electromagnetic lock that is part of the Buy American Act.
Currently we do not offer an electromagnetic lock that can be used with the BAA....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial
Will the 490 Armature mounting fastener pack P44489110 work with an M490DE/DEP?
Not as is, however, the difference in the armature mounting kits is the length of the armature bolt. The M490DE/DEP has a longer armature bolt than the M490.  If just needing the washers, the M49...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series
On an M490DE the green LED is always on and door is unlocked. When I present a credential, the LED turns off, lock remains unlocked and never relocks.
Most Likely, an access control panel (ACP) has a closed contact going to the reset and release terminals....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series