Schlage GF3000 - Components of P280135 Mounting Hardware Pack
The parts included in the mounting hardware pack are: (14) SCREW, 10-24 X ½ (2) SCREW – PAN HEAD 10-32 (8) SCREW - #10 SELF TAP (1) HEX WRENCH (2) MOUNTING TAB – MAGNET, GF3000 ...
System Components » Electromagnetic Locks » GF3000 Series
Schlage GF3000 - Installation on Glass Door with Rail
The GF3000 can be mounted in this situation as long as there is sufficient room to mortise and mount in the frame rail and door. Or you may be able to use the surface mount series GF3000. ...
System Components » Electromagnetic Locks » GF3000 Series
GF3000 coil does not float
Current production GF3000 have a fixed , solid coil. Previous models excluding the BRD had spring load floating coils. This allowed the coil to drop and meet the armature, Engineering is reviewing t...
System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics
Will mag locks operate with voltage ranges between 12vdc and 24vdc?
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that volt...
System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP, should the Alarm Output, put out 30V@1A?
This is contact rating, and not the output; it is a dry contact.  ​You can run a max of 30V and up to 1 amp through the Alarm Output to drive an LED, horn or other, but the output itself ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
Why does the M490DE/DEP delays for a few second before releasing after the 15 seconds egress?
Check the Armature, it may be on backwards....
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
On the M490DEP are the wires going to the Alarm, opened or closed?
Alarm is an OUTPUT.  The contact closes when the lock goes into full alarm. ​When lock is not in alarm, the contacts are open ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
How do you wire up an M490DE to a 900-4RL with a FA on it so it will drop power in a fire alarm condition?
Any powered outputs on the 900-4RL will lose power if the FA board on the 900-4RL opens, use a dry relay to trigger release input, the Maglock should be on NO1 and C1 and a jumper on I1 and SC....
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What size screws are used with the M490 mag locks?
Inside mounting bracket screws are USS 10-24 x 1/2" Outside mounting bracket screws are USS 10-32 X 3/4" Magnet Screws - Are 1/4 - 20 thread 3/16 hex total length 2 ¾ Cover Plate Screw ...
System Components » Electromagnetic Locks » M400 Series | System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
What should the Ohms read on a coil in a M490G?
Approximately 30-40 Ohms (the one on our test bench measured at 32.8 Ohms on each coil)....