AD200 gets 9 red blinks then opens
Red blink of left means AA batteries are low, Red blinks on right means coin cell is low, (2032)replace battery then press S1 to reboot firmware...
Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Do AD and CO Series locks support the Yale FSIC 7pin cylinder?
There is a new supported competitor Yale 7 pin FSIC removable key cylinder option for AD and CO series locks: Order Exterior Lever (Less Cylinder) - JD YA7 supporting Yale FSIC 7 Pin (Yale 1220 ...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
CT5000, or AD Lock will they work with iclass readers?
The Ct 5000 would require a third party reader capable of reading iclass and decrypting data to provide a wiegand output.The AD series now has an MI/ MIK reader availabe for the more common iClass sec...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Schlage Electronics
How does an AD or CO lock with keypad go into lockout mode?
An AD or CO lock with keypad will go into lockout mode and stops responding to key presses after 20 wrong key presses and then the lock remains in timeout and unresponsive for 30 seconds.Wait 30 secon...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Offline | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
How often should I replace the coin cell in an AD or CO Series lock?
Under normal circumstances (i.e., no prolonged loss of AA battery power), the coin cell should be good for the advertised shelf life of the battery, which is typically seven years.The coin c...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
How do you remove an AD or CO Series Lever?
To remove an AD or CO series lever requires a push pin type Pin Wrench (included with all new locks) or Lever Removal Tool used to depress the knob stop pin.The knob stop pin is located through a sma...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Why do I get an Error 601 with my SUS/HHD when loading new FW on my AD-Series device?
Affected Product:
Starting March 2014 the below AD-Series products were manufactured with AD.A.60 and will require SUS 5.0.2 or newer to update firmware,All AD-Series products - AD-400/401,
AD300/3...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
How do you pull an AD-200 Audit?
Audits are retrieved via the Schlage Hand-Held Device (HHD) and the Schlage Utility Software (SUS). Start the SUS program on the HHD and sign in as either an operator or a manager. Connect the USB cab...
Schlage Commercial » Electronic Locks » Offline » AD 200 Series
Is the Hager Rim Exit device model 4701 compatible with the AD or CO 993 exit trim.
Is the AD or CO -993R compatible with a Hager Rim Exit
device # 4701?No, there has been no testing of this device. There is an issue with mechanical alignment with this exit. The Hager device has not ...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Why can't Auto-Unlock schedules span midnight?
Auto-Unlock schedules that need to span midnight are required to be broken up into two non-overlapping and separate schedules. The two schedules will be, one schedule that ends at 11:59 PM and a...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Offline | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » CM Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » Cobra Series | Schlage Commercial » Electronic Locks » Offline » King Cobra Series | Schlage Commercial » Electronic Locks » Standalone/Offline | Schlage Commercial » Software » Schlage Express | Schlage Commercial » Electronic Locks » Offline » CO 220 Series