Category: AD 300 Series

(Results from 61 to 70)
Where can I find a parts listing for AD series Locks?
Where can I find a parts listing for AD series Locks? (Includes AD-400, AD-300, AD-250, AD-200)Download link for:  AD Series Service Manual...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Schlage Electronics
With the AD-300-993R with Falcon 25 exit trim. The templates for metal door states to use Von Duprin 98-R/99-R, 9827/9927, 22-R, or 2227 Series Exit Device Template. Can they use the same template for Falcon 25 as well?
Yes. Since we only show applicable holes for the 993R device, it will work with any of the exit devices that are compatible.      The exit device prep should be done on the door f...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series
Can AD locks be order with a split finish?
Yes.  In the part number, first state the exterior and then the interior.   Example: AD400-CY-KP-RHO-626-625…...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series
Does the PIB300 connected to AD300 both require separate power supply?
They could be powered by same unit, if they are close enough. With data pair and power pair of wires the power supply can be at the PIB300 feeding both AD300 locks, as long as current suppli...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series
What is the reason to wire daisy chain 2 AD300 to a PIB?
It is the suggested method of wiring the locks to the PIB per engineering. It will it work if you wire each lock directly to the PIB, but daisy chain is the preferred method. Make sure to address...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series
Will an AD Series lock retain reader settings if the reader module is replaced with one of the same type?
Yes, be sure to press the “S1” switch on the main board after installing the new reader so it will be recognized....
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
For an AD-400 with an Athens lever, what is the distance from the tip of the lever to the surface of the door?
It is approximately 2 ¼ inches.  Some door designs have raised panels and may need more clearance. The Tubular, Sparta, and Rhodes designs may not have enough distance to accommodate these app...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
Where can I find the UL listing information for AD-Series locks?
Link to the UL database entry:   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=GYQS.R8458&ccnshorttitle=Electrically-controlled+Single-point+Locks+and+Latches...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series
Can the inside push button operate on an AD300 with a 40 function using a PIB-300, or is it required to use RS-485?
The AD300 must be connected to a 485 partner that has the capability of understanding the IPB.  Not all partners utilize the IPB. The PIB300 will not let the IPB work due to the Wiegand communica...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series
Will the AD300 /AD400 work with a Precision 21 exit trim device ?
·         Not recommended-  The competitors RX switch has not been tested with the AD300/400 / Access Control Systems ·     &nb...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series