What are the dimensions of PIB300 controller enclosure?
The dimensions of the PIB300 controller enclosure is:   7.1" x 7.1" x 3.0" ...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics
Do the MT2, and Si, have different formats on the readers?
The MT2 and the Si readers are two different readers. The MT2 is MultiTech reader that can read smart and prox cards on an AD locks.  It can only read the encoded sector of Schlag...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Readers » Smart Card
On the PIM400-TD2, is the tamper active all the time?
If the tamper button is not connected to the tamper terminals, the PIM400-TD2 is NOT in a tamper state. If the tamper button is connected and they have the cover off it is in tamper state. I...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics
When an AD online lock is in degraded cache mode does it record audits?
When the AD lock is in degraded cache mode, no audits are recorded....
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics
Why does my AD400 give a door forced alarm at the panel when the mechanical key is used to release the door?
The mechanical key is really supposed to be used if the batteries die or in other emergency situations.  Using the mechanical key is not electronic access granted.  If there is no access g...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics
Do AD locks report the key override to access control panels?
Yes, the AD's have a key override switch output. Most access control systems will give an MLO alert but some do not. ...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Security Management » Schlage Electronics
What is the Schlage Button LED indication when a networked AD lock is put in PRIVACY MODE with the inside pushbutton?
For networked AD locks such as the AD400 and AD300, this function is completely dependent and controlled by the Access control system....
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series
If using AD400 running with PIM400-485's, can the PIMS be T Tapped into the RS485 wires, will this cause an issue?
If the T-taps are short it should be ok less than 10ft. PIM400-485 modules are easily daisy-chained, which is a preferred method....
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series
Where do you connect the GRND output on the J5 terminal of a PIM-400-485?
It should be wired back to the ground on the Access Control Panel (ACP) RS-485 Terminal. ...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics
When should I use shims with an AD400 lock?
When you have a door that is thinner than 1 3/8 inches. Then shims would be ordered in increments of 1/8 inches....
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 400 Series