Are the Locknetics TB series UL listed?
No,
there are no UL ratings on the Locknetics TB series. The Touchbar is a request to exit device, that
is usually installed as a redundancy to other access control devices for
non-fire rated in...
Schlage Commercial » System Components
Is the 653 key switch cylinders available with Primus?
Order the 653 key switch as 653-XX, then specify a Primus cylinder on a separate line item.
Specify a mortise cylinder 1 1/4" length with a straight cam.
...
Schlage Commercial » System Components | Schlage Commercial » System Components » Keyswitches
How do I set the relay time delay on the Locknetics WS200?
All jumpers installed will give you 0.5 secondsJumpers 3 & 4 installed will give you 5 secondsJumpers 1 & 2 installed will give you 10 secondsAll jumpers off will give you 20 seconds...
Schlage Commercial » System Components | Schlage Commercial » System Components » Electromagnetic Locks
Is the 672 Series, pushbar UL rated?
Yes, it is rated for UL 294 and UL1034...
Schlage Commercial » System Components | Schlage Commercial » System Components » System Accessories » Request to Exit Devices
What is the difference between the 692 SmartBar and 672 TouchBar?
The 672 just has a switch in it that open and closes when pressing on the push bar. The 692 does not move and uses an infrared light sensor across the front of the bar to activate a relay when ha...
Schlage Commercial » System Components | Schlage Commercial » System Components » Smart bar | Schlage Commercial » System Components » Touch bar