Schlage MT-series Readers and F2F Protocol (Used by GE Systems)
Schlage MT readers cannot function using F2F protocol.  The readers output wiegand or RS485 OSDP communication, not F2F.  In most cases, a wiegand-to-F2F data converter device is used. &nbs...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Proximity | Schlage Commercial » Readers » Smart Card
Schlage SM10 - Not Compatible with OSDP 485 Configuration
The SM10 readers are do not support being ordered as -485 configuration.  The unit supports wiegand output only. If -485 OSDP is needed, recommend using MT11 or MT15 instead, or as of late 202...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Smart Card » SM 10
How can I assign individual OSDP ADDRESS to the MT readers?
Yes you can, you will need configuration cards for the addressing:Here are the part number for the specific addresses:CE-401-447 OSDP Address 0 (Default)CE-401-448 OSDP Address 1CE-401-449 OSDP Addres...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries
What speed does the Schlage RC devices communicate at?
The Schlage RC reader communicates at 100MB half or full duplex ...
Schlage Commercial » Readers | Schlage Commercial » Readers » Multi-Technology
What is the new part number for the FE410 (Control) strike combination?
Old part number 10-121 has been replaced with 10-152 (Standard – Combo, Square Corner 10-094 & 10-026). This part is not sold separately. ...
Schlage Commercial » Readers » Multi-Technology
What’s the difference between OSDP and OSDP Secure?
The readers: MT15-485 and MT11-485 MTB15 (when using the 485)  Support OSDP secure (encrypted) or open. This is controlled by the Access Control system. ...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Do you need a config card for the MTB readers to communicate OSDP?
No... MTB Readers are able to communicate RS485 / OSDP by default. However, you will need a configuration card if you want to change the OSDP address. ...
Schlage Commercial » Readers | Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries
How do I change the track on an MTMS15 magstripe reader?
Power cycle the reader, wait for the beep then present configuration card to the reader within 60 seconds (see chart below for config cards). ...
Schlage Commercial » Credentials » Magnetic Stripe | Schlage Commercial » Readers » Magnetic Stripe Readers | Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics
Can your multi-technology readers read Kantech XSF format prox cards
The Kantech XSF cards are proprietary secure prox cards. Our multi-technology readers can only read standard prox formats.  Not proprietary formats. ...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Electronic Locks » NDE Series | Schlage Commercial » Electronic Locks » LE Series
Can the RSO update MTB readers (firmware) with a profiler, like they would on an MT reader?
Profilers do not work on MTB readers, MTB reader firmware is updated through Engage, so you would need to commission the reader to a partner site then connect and update firmware. MTB reader firmwar...
Schlage Commercial » Readers » Multi-Technology | Schlage Commercial » Readers » Multi-Technology » MTSeries | Schlage Commercial » Readers » Multi-Technology » MTSeries » Schlage Electronics