Category: AD 250 Series

(Results from 11 to 20)
Will an AD series -993R lock work with a Von Duprin 9847 / 9947 Panic Exit Device?
AD and CO series -993-R model locks will work with most Von Duprin 98/99 series model push bars exit devices – Rim, CVC - Concealed Vertical Cable or CVR - Concealed Vertical Rod AD Series -200/250/...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Do AD and CO Series locks support the Yale FSIC 7pin cylinder?
There is a new supported competitor Yale 7 pin FSIC removable key cylinder option for AD and CO series locks: Order Exterior Lever (Less Cylinder) - JD YA7  supporting Yale FSIC 7 Pin (Yale 1220 ...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
How does an AD or CO lock with keypad go into lockout mode?
An AD or CO lock with keypad will go into lockout mode and stops responding to key presses after 20 wrong key presses and then the lock remains in timeout and unresponsive for 30 seconds.Wait 30 secon...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Offline | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
How often should I replace the coin cell in an AD or CO Series lock?
Under normal circumstances (i.e., no prolonged loss of AA battery power), the coin cell should be good for the advertised shelf life of the battery, which is typically seven years.The coin c...
Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
How do you remove an AD or CO Series Lever?
To remove an AD or CO series lever requires a push pin type Pin Wrench (included with all new locks) or Lever Removal Tool used to depress the knob stop pin.The knob stop pin is located through a sma...
Schlage Commercial » Electronic Locks | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Why do I get an Error 601 with my SUS/HHD when loading new FW on my AD-Series device?
Affected Product: Starting March 2014 the below AD-Series products were manufactured with AD.A.60 and will require SUS 5.0.2 or newer to update firmware,All AD-Series products - AD-400/401, AD300/3...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 300 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series
Is the Hager Rim Exit device model 4701 compatible with the AD or CO 993 exit trim.
Is the AD or CO -993R compatible with a Hager Rim Exit device # 4701?No, there has been no testing of this device. There is an issue with mechanical alignment with this exit. The Hager device has not ...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Is the Schlage ND JD YA6 lever the same as the CO lock JD YA6 lever?
The levers are not compatible with each other.Schlage ND lever is part 03-255 for locks manufactured on or after January 30, 2017Schlage ND lever is part 03-055 for locks manufactured prior ...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Electronic Locks » Offline » CO 220 Series
Level 2 Factory Default clears special card configuration from AD lock readers
Be aware when  trouble shooting  AD lock  issues that a L2FD( level 2  factory default) will clear any special card config in the reader.The L2FDR is a common practice to restore a...
Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Standalone/Offline
What is the low battery threshold for AD and CO Locks?
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved battery voltage levels. These are approximate values/levels which can vary with measurement meters...
Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series