Is the L9000 certified for positive pressure fire tests?
See the UL Online Certifications Directory at www.ul.com/database for additional information....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage
Which L series lever designs are handed?
The 12, Accent, Asti, Merano, M61, M62, M63, M85 and ME1, ME2 lever designs are handed and cannot be changed in the field.  The lock case can still be changed when using these lever designs. &nbs...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage
How do I order the LM9300 multipoint lock?
The mortise lock would be priced from the Schlage commercial PB. (Please refer to the current PB for details) There is an add to the base price for the multipoint lock option.The rods, door and door f...
Schlage Commercial » Doors and Frames | Schlage Commercial » Doors and Frames » Doors | Schlage Commercial » Doors and Frames » Frames | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series » Schlage | Schlage Commercial
Can a thumbturn cylinder be used on the L9453?
A thumbturn cylinder will not provide the intended operation.  The L9453 requires the actual thumbturn hub to be rotated the additional 20° to unlock the outside lever once the deadbolt has been...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series » Schlage
Does Schlage recommend the use of a varistor for the electrified L9000?
Per the instruction sheet, a varistor rated at 35 V (peak recurrent) may be used for transient voltage protection....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9200
How is the RX switch handed on the L9010?
The RX switch doesn't require handing as there is not a handing screw on the L9010 lock body. The RX switch will trigger both the outside lever and the inside lever. ...
Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage
Are the LM9200 locks available with RX or LX option?
The design of the LM9200 lock cases do not allow for the LX or RX features.   ...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9200
Is the HL6 9000 EO / EN option supplied with a blank plate?
The HL6 9000 EO/EN does not come with a blank plate for one side....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Push/Pull Latches | Schlage Commercial | Schlage Commercial » Mechanical Locks » Push/Pull Latches » HL6/PL7/PL8 Series
What is the maximum gap allowed for door position switch (DPS) operation on the L9000?
For L9000 door position switch (DPS) operation, the door gap should not exceed 3/8". The DPS switch becomes unreliable around 1/2" door gap....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage
Is the L9000 with N escutcheon available for a 1-3/8" thick door?
Per the Schlage price book. N escutcheon trim is only available for 1-3/4" thickness up to 2-1/4" thickness....