RU strike identification for early Corbin Russwin applications.
The RU lock can be requested as a retrofit for early Corbin Russwin Unit locks. Several types of strikes are offered depending on the strike conditions but two are very similar with the exce...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued
How do I change the handing on the RU lock?
The RU lock is factory handed for a Left hand or Right hand door. For reverse handing ( Left hand reverse and Right hand reverse doors) see step 9 of the installation i...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued
Where can I find timing instructions for the Falcon T lock?
To verify the timing on a T561, function test the outside lever after locking it.
To lock the key should only rotate 180 degrees (Not 360 degrees as Schlage does)
A prop...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series
What is a keycam?
A keycam is a sub component inside a cylindrical chassis (such as AL or ND) that provides the interaction required to lock and unlock the chassis....
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series
What is the RU lock?
The RU series from Falcon is a pre-assembled unit lock designed to retrofit existing unit locks manufactured by Falcon, Corbin Russwin and Yale. It exceeds ANSI Grade 1 specifications and is UL/...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued
Can I get the RU series with a Schlage Full Size Interchangeable core?
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock.
Example: RU581J IC-SC...
Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued
Outside lever on the T and RU 571's won't unlock after egress.
Replace the lock chassis as necessary for any T locks exhibiting this issue. RU locks need to be replaced entirely.
...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series
What do the letters and numbers mean in a Falcon lock part number?
Falcon Series locks are available with a number of functions, cylinder options, lever/knob styles, latch, strike and finish options. The Falcon Locks Catalog can be helpful in determining what options...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series (Falcon) | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » K Series - Discontinued
Do the RU and T series use the same latches?
The RU and T series latches are not compatible....