Category: 98/99 Series

(Results from 31 to 40)
Motorized Chexit Troubleshooting: When motorized Chexit device tries to arm, pushpad remains unlocked and internal alarm is pulsing fast after 2 seconds.
1.Chexit motor cable is disconnected. This cable should connect the Chexit module to the motor assembly.2. Chexit motor cable has an open connection,  or wires are in wrong order.3. Chexit motor ...
Schlage Commercial » Exit Devices » Mechanical Accessories | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Motorized Chexit Troubleshooting: When Chexit attempts to arm, pushpad remains unlocked and internal alarm is pulsing fast.
1. Door position switch (DPS) contact is open. Verify the DPS contacts are closed when the door is closed.2. Door position switch wiring/connection is open. With door closed, verify the DPS wiring has...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
On the 9947 Installation Instructions, the text says to follow the red and blue instruction cards on rods. Is this correct?
As of 2017:The cards are now white and tan,  not red and blue....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
I have an EL9947 in stock. Can I use this as a manual exit device without connecting to a power supply.
Yes, any EL device will operate as a manual exit device when not connected to power. ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Can the Von Duprin 9447 be cut down to fit a door narrower than 36”?
 Can you order a 9447 to fit on 36” door yes, can you cut down in the field a 9447 of any size no cut down in field ....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Can the 373L be used with the 98/99 series
Yes.  The 373L with EURO SPINDLE is available as an engineering special....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
What does MD describe? Example: My customer has this listed as RX99L-F E996L 06 FS 4' MD US26D?
In this example,  MD stands for Metal Door....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
What is QM for Von Duprin?
Accepting orders for the QM option on 98/99 Rim Exit Devices, 33A/35A Rim Exit Devices, and 996L/L-BE-R/V Trims starting 4/23/2018. Accepting orders for the QM option on the 98/9927 Surface Vert...
Schlage Commercial » Exit Devices » Touch Bar | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin | Schlage Commercial
Will the QM option make my door completely silent?
The QM option reduces the operational noise of the Exit Device or Trim during normal operation.Other factors can cause the complete door system to make noise. To be most effective, combine the QM d...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Von Duprin
Can a 9947WDC-F LBR device use the 283 strike for wood frames?
A 9847WDC-F LBR or 9947WDC-F LBR device must use the 338 strike to maintain its fire rating. Using a 283 Strike in a wood frame would void the Fire Exit Hardware UL label of the 98/9947WDC-F LBR dev...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin | Schlage Commercial