Category: 98/99 Series

(Results from 21 to 30)
Is the centercase of the WS99 or WS99 handed?
Yes. The windstorm devices WS98 and WS99 center cases must be ordered with Handing from the factory....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can the CON-26 handle the 16A inrush for an EL?
Yes, from the device to the door side of the power transfer.Use the CON-6W on the frame side to connect with 12AWG or 14 AWG field wiring.  ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin
Can 996K trim be changed to a lever (996L) in the field?
No.  The 996K cannot be changed to a lever function in the field.  These functions are manufactured differently at the factory, including press-fit parts that could not be changed in the fie...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can a QEL conversion kit be used on an AX device?
Yes. QELX baseplate converstion kit or HD-QELX Baseplate converstion kits can be used on Von Duprin AX devices.  ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Does 36" extension rod kit for 98 / 99 device service 1 or 2 devices?
Does 36" extension rod kit for 98 / 99 device service 1 or 2 devices?Answer: The extension rods are only designed to extend the top rod for one device only, not two.  The kit only comes with one ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can the Chexit trim output be controlled when the Chexit key is in disarmed position?
This information applies to the "new" Chexit after 2015. When the Chexit key switch is in the disarmed position,  the trim output will keep the trim secured  (powered if FS,  not p...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can the auxilary fire latch (AFL) be mortised into a Steelcraft door, or must it be surface-applied.
In general, if the construction of the door covers AFL mortising in the door manufacturer's file, then this is ok.Note that Steelcraft does not have this information in their files.Modifying a doo...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can Chexit or Delayed Egress Be Used With Windstorm / FEMA openings?
No, delayed egress hardware cannot be used with FEMA openings....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What are some causes for a Von Duprin 996L lever to droop or sag?
The lever may be in the break away position. The 996L has a break away design.  If the lever has been forced down to a 6 o’clock position, it needs to be firmly pulled up to a horizontal posi...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Can you order a 9827 or 9927 panic device Less Bottom Rod (LBR)?
Panic Rated 98/9927 and 98/9947 devices can be ordered Less Bottom Rod (LBR).The price book does not specifically reference this option on panic rated devices, but there is no additional charge.There ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series