Category: 8310 Series

(Results from 1 to 10)
What is the part number for the wire harness or cable for an LCN DMSS, 8310-804-1 or 8310-804-2?
The 8310-804-1 or 8310-804-2 DMSS Harness cable is part number:  8310-847. Cable is also listed in the instruction manual as:  761467 ...
Automatic Operators » Electromechanical » Senior Swing | Automatic Operators » Electromechanical » Senior Swing » LCN | Door Controls » Automatic Operator | Door Controls » Automatic Operator » 8310 Series | Door Controls » Automatic Operator » 8310 Series » Falcon | Door Controls » Automatic Operator » 8310 Series » LCN
Will the 9550 series Senior Swing work with a strike and auto flush bolts?
The 9550 series Senior Swing WILL NOT work on a pair of doors with Electric Strike and auto flush bolts because you cannot sequence the door openings with a 9550 simultaneous pair operator.&nbs...
Automatic Operators » Electromechanical » Senior Swing | Automatic Operators » Electromechanical » Senior Swing » LCN | Door Controls » Automatic Operator » 8310 Series | Door Controls » Automatic Operator » 8310 Series » LCN
How do you program the 8310-865 RF receiver?
To program the 8310-865 receiver: Set the dip switches 1 to the "OFF" (pulse) position. Set the dip switches 2 to the "OFF" (0.5s) position. Momentarily press the " No Delay" or "Del...
Door Controls » Automatic Operator » 8310 Series » LCN
What wire gauge is recommended for LCN hardwired actuators?
LCN recommends an 18 AWG (minimum) wire size (gauge) to the 8310 Series hardwired actuators....
Door Controls » Automatic Operator » 8310 Series » LCN
Why would an 8310-865 RF Receiver for power operator have a flashing "RED" light?
When the "RED" LED on the 8310-865 RF Receiver is blinking, it is receiving an RF signal (interference) from a non programmed device. When receiving this type of signal, it will not program correct...
Door Controls » Automatic Operator » 8310 Series » LCN
8310-865 receiver and sequence.
RF sequential operation requires the use of of a minimum of 2 receivers (8310-865). Depending on the desired operation required (if using access control), it may require up to 4 receivers (8310-865). ...
Door Controls » Automatic Operator » 8310 Series » LCN
What is the 7910-956 direct crossover?
The 7910-956 actuator direct replacement is the 8310-856 actuator....
Door Controls » Automatic Operator » 8310 Series » LCN
What actuators can be used on the 8310-866 Bollard post?
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired - ...
Door Controls » Automatic Operator » 8310 Series » LCN
What are the power requirements for the 8310-865 (433 MHz) receiver?
The input voltage for the 8310-865 (433 MHz) receiver is 12-24 VAC/VDC +/-10%, the current draw is 250mA (0.25A)....
Door Controls » Automatic Operator » 8310 Series » LCN
Is the 8310-849 Door Sequencer still available?
The 8310-845 is now a combination "Time Delay Relay / Door Sequence" module. In 2010 the separate 8310-845 "Time Delay" module and 8310-849 “Door Sequencer” module were combined into a "common...