Category: Senior Swing IQ

(Results from 1 to 5)
What is needed to convert the legacy bottom load Senior Swing into a IQ Senior Swing?
A legacy 9500 or 2800 Sr Swing operator can be converted into a 9500IQ or 2810IQ with the upgrade kit. Upgrade kit part #'s below.     SSIQUPGRADE-SD – This is to upgrade a single doo...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Electromechanical » 9540IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9530IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ » 9550IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ
What is the Hold open delay time adjustable to on an LCN Sr Swing IQ Control Box?
The Hold Open Delay time on the Sr Swing IQ Control Box is adjustable from 1-60 seconds (default 5). See here for complete Sr Swing IQ Control Box instructions...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » 9540IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9530IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ » 2810IQ
What is the Power Assist feature on an LCN Sr Swing IQ Operator?
The LCN Sr Swing IQ operators have a power assist feature available in the control box programming.When turned on, the operator will assist with manual door opening.  The door will feel lighter b...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » 9540IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9530IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9560IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ » 2810IQ
Does the LCN Sr Swing IQ operator have an adjustable lock delay feature?
The LCN Sr Swing IQ operators have a lock delay feature in the control box that is adjustable from 0-2 seconds.   Delay Time options are .5, 1.0, 1.5, or 2.0 seconds   This will de...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » 9540IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9530IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ » 2810IQ
On the LCN Swing IQ, what is the measurement between the top and bottom set of holes on the 9540IQ-10 base plate?
The measurement between the top and bottom row of mounting holes on the 9530IQ, 9450IQ, 9550IQ, amd 9560IQ base plates (-10 or -10-DD) is 13/16".If a customer is wanting to Predrill the mounting holes...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical » 9540IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9530IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ » 9550IQ | Schlage Commercial » Automatic Operators » Electromechanical » 9560IQ | Schlage Commercial » Door Controls » Automatic Operator » Senior Swing IQ