Category: Fire Life Safety

(Results from 1 to 10)
Do I need to order the LCN 4040XP closer X ST-3596 to get the cover screw to secure the snap on cover to the cylinder?
As of June 27th, 2018--- the cover screw is now standard in the screw packs for the 4040XP, 4040XPT, 4000T, and 4040SE so ST-3596 is no longer needed.  ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series » LCN | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial » LCN | Schlage Commercial
If I order replacement parts from LCN such as an Arm, cylinder, Track, PA Shoe, and Cover, do I need to order screws for installing?
No, because individual or replacement parts from LCN come with the screws needed to mount them.    One exception is LCN SEM magnet parts, see here.   ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Accessories | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » LCN | Schlage Commercial
What are ANSI BHMA hardware grades?
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware on...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Exit Devices | Schlage Commercial » Mechanical Locks | Schlage Commercial » Ives | Schlage Commercial » Von Duprin
How do I to use an overhead stop with a door closer?
Integrating an overhead stop with a door closer usually requires that both pieces of hardware be mounted near the same locations on the door and frame usually causing a conflict. In most cases, modifi...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Accessories | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Glynn-Johnson | Schlage Commercial » LCN
What is UL294 or UL1034?
UL 294 is a standard for Safety Access Control System Units.  UL 294 applies to electrified hardware that control access but restricts free egress. UL 294 does not apply to electrified hardw...
Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Electronic Locks » Networked | Schlage Commercial » Electronic Locks » Networked » AD 300 Series | Schlage Commercial » Electronic Locks » Networked » AD 400 Series | Schlage Commercial » Electronic Locks » Offline » AD 200 Series | Schlage Commercial » Electronic Locks » Offline » AD 250 Series | Schlage Commercial » Electronic Locks » Offline » CO 100 Series | Schlage Commercial » Electronic Locks » Offline » CO 200 Series | Schlage Commercial » Electronic Locks » Offline » CO 250 Series | Schlage Commercial » System Components | Schlage Commercial » Electronic Locks » Offline » CO 220 Series | Schlage Commercial » Electronic Locks » NDE Series
What can clean oil off a door that had a closer leak fluid?
To break down the oil molecules use an acidic cleaner or even use vinegar to wipe down the door. May also try using Simple Green to remove oil if hasn't stained   ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial
What type of finish is on the LCN SEM 7800 magnets?
They are supplied in a Powder Coat finish.  Standard finishes are Alum and Dark Bronze. ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » SEM 7800 Series Magnets | Schlage Commercial
When did LCN change the bushings on their rollers?
First check installation/templating as improper installation can lead to wear and tear on the roller and thus cause issues.   We did launch a new roller design on Feb. 8, 2016 ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » 3130 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » High Security » 2210 Series | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » LCN | Schlage Commercial
Why is my manual door closer making a swooshing sound when the door is cycled?
With closers being hydraulic in nature and fluid being pushed thru the cylinder and ports you will always have some level of noise and this can be amplified by the type of door the unit is on. &n...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » OHC100 Series | Schlage Commercial » Door Controls » Concealed » 3030 Series | Schlage Commercial » Door Controls » Concealed » 3130 Series | Schlage Commercial » Door Controls » Concealed » 330 Series | Schlage Commercial » Door Controls » Concealed » 5030 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » High Security » 2210 Series | Schlage Commercial » Door Controls » High Security » 4210 Series | Schlage Commercial » Door Controls » High Security » 4510 Series | Schlage Commercial » Door Controls » Overhead Concealed » 5010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 6030 Series | Schlage Commercial » Door Controls » Overhead Concealed » OHC 100 Series | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 1000 Series | Schlage Commercial » Door Controls » Surface Mounted » 1040 Series | Schlage Commercial » Door Controls » Surface Mounted » 1050 Series | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial » LCN | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050T Series
When did LCN start shipping the new 3034SE roller/slider with a wear pad?
Engineering redesigned the SE roller/slider to include a wear pad and it was launched and started shipping with SE orders on Thursday December 13th 2018.  See here for product image.  ...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » LCN | Schlage Commercial