Which template is used to prep the door for the L9000 SL1 Trim?
There is not a specific template for the SL1 trim when used with the L9000. Use the template listed under the appropriate L9000 Lock Function with Rose Trim....
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage » Schlage | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage
Has an update been made to the thumbturn and cointurn rose on the Schlage L9000 series?
An update was made to the thumbturn rose for sectional trim shipping on or after June 6th 2021.
The new design provides a more stable thumbturn and coin turn with less play/wobble than the ...
Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9200 | Schlage Commercial
Does Schlage have video installation for the HSLR trim?
Please click here for link for video installation instructions....
Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Should I use Dummy trim on an Inactive door using Automatic Flush Bolts?
On a door with automatic flush bolts, the inactive leaf can’t have a dummy lever, push bar, or other hardware that would make it appear that the Inactive leaf could be operated for egress. N...
Schlage Commercial » Exit Devices | Schlage Commercial » Mechanical Accessories » Flush Bolts and Coordinators | Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Mortised
Can the paddles on the HL6-9000 be mounted vertically on thumbturn functions?
When the cylinder application is used, the paddle on the key side may be mounted in the down or horizontal position, or when the thumbturn application is used, paddles must be mounted in the horizon...
Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial | Schlage Residential » Schlage Mechanical
Is there an offset between the Center Line of the Strike and the Lock on an HL6-9000?
The Strike Center Line is located 3/8" or 10 mm above the Lock Center Line.
Please click here for a link to the Installation Instructions; reference step 2a.
...
Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage » Schlage | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Push/Pull Latches » HL6/PL7/PL8 Series