What is the difference between the Von Duprin standard baseplate return spring package 090039 and the LBR (less bottom rod) baseplate return spring package 090088?
Current baseplate spring 090039 Used with 2227/27-F, 33/3527A/27A-F, 98/9927/27-F (Standard and LBR) May be used for all standard and LBR devices produced after 1995 Was redesigne...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
How do I convert a Von Duprin 98/99 series Rim or Vertical Rod/Cable device from classroom function to nightlatch (storeroom) function)?
You need NL drive screw if you don't have one.  Part #090074 for a package of 10. This is the set screw that goes in the master cam on the back of the device center case. Remove the NL...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
If I need to adjust my cable length on a Von Duprin concealed vertical cable exit device, can I reuse my existing cables?
New cables need to be ordered if the cables need to be resized. Once the end fitting nut is tightened, it cinches down on the cable such that the nut can't be loosened or readjusted....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can an existing 98/9949 device be converted to a less bottom latch (LBL) application?
The 98/9949 panic rated exit device can be converted to less bottom latch (LBL).  To convert the device, you will need to detach the bottom cable from the top latch.  Then you must remove th...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
What is unique about the Von Duprin AX device?
The force required to activate operable parts is 5 pounds maximum. There is a unique UL label on it that states it meets California Building Code. The shock absorber is different from...
Schlage Commercial » Exit Devices » Touch Bar » 22 Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Can the M996 trim be converted to an E996 trim?
Yes, the M996 can be converted to an E996. For trims being used with rim, vertical rod, and vertical cable devices, use part number 050672. For trims being used with mortise lock devices, us...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
What trim may be used with a Von Duprin ESL (Emergency Secure Lockdown) exit device?
Per 2018 IBC 1010.2.8, for locking arrangements in educational occupancies: The door shall be capable of being unlocked from outside the room with a key or other approved means. An outside night...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Is there a security screw pack for the 98/9949 device?
A security screw pack is available for the 98/9949.  It is the same security screw pack used with the 98/9947....
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Is it possible to have dogging on exit devices with either of the double cylinder (-2/-2SI) options?
It is not recommended to combine a double cylinder and a dogging option on an exit device.  The device could be in a dogged (unlatched) state even though the double cylinder indicates a locked st...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Are the old 992 mounting studs (Part 969546) still available?
The old style 992 mounting studs (Part 969546) have been discontinued and are no longer available....