What did the K suffix for the old D800 and D400 represent?
This was not the standard thumb-turn. This thumb-was longer and was a black powder coat (622) finish. Also, the shape was not the same as the standard thumb-turn....
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial
What replaced the D891BK deadbolt from Falcon?
There is no current option to replace the D89BK. This was a deadbolt with a 2" handicap thumb-turn inside and a blank occupancy indicator on the outside....
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Falcon | Schlage Commercial
What did the Falcon D871 indicator look like?
The Falcon D871 indicator plate was a square shaped plate. The part number for the indicator was 009151-001.The D800 series is no longer offered nor are parts. It was replaced by the D200 series...
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Falcon
What is the part number for the extender rings (EXT) shown on the deadbolt IC assembly instructions P515-800?
The Interchangeable Cylinder Assembly deadbolt assembly instructions P515-800, identify the extender rings by "EXT". Replacement rings can be purchased as a kit, 36-071 which include both the 36...
Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage
Can the UL Listed Falcon D100 and D200 deadbolts use a 1 1/2" hole door prep?
The door prep hole for the UL listed Falcon deadbolts needs to be 2 1/8". The fire cup will not fit in a 1 1/2" hole door prep. ...
Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon
Can the multi-tailpiece cylinder 40-100 be used in B660?
As far as fit and function, the cylinder will work, however the B660 tailpieces are not included in 40-100 kit.Additionally, the B660 requires a disc (C603-098) and a washer (B610-071)....
Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage
What is the part number for the blank plate for D261M and B581?
The part number for a blank mounting plate for the D261M and B581 is 38-034....
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage | Schlage Commercial
Can a B250 series fit a 2-1/8 door preparation?
No, there is no adapter available for the thumbturn rose to allow the B250 to fit on a 2-1/8" bore. ...
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage