Does Schlage make a retrofit cylinder for Sargent 11 Line locks?
The Schlage 24-119 KIL cylinder will operate the 7,8,10,10x and 11-line levers locks. Click here for more information on upgrading key systems in Sargent locks. ...
Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Schlage
What is the maximum adjacent cut specification or MACS?
NOTES:Schlage Conventional/Full Size keyway families are: Obverse, Reverse, Paracentric (Numbered), Quad, Everest C, Everest D, Everest 29 S, and Everest 29 T.Schlage Small Format/SL keyway families a...
Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Key Systems » Keys | Schlage Commercial » Key Systems » Keys » Keys | Schlage Commercial » Falcon | Schlage Commercial » Schlage
What is a "0" bitted cylinder?
0-bitted refers to a cylinder with zero pins in each chamber and can be operated with a key with all zero cuts. Cylinders are shipped in this configuration to allow repinning in the field and ke...
Schlage Commercial » Key Systems | Schlage Commercial » Key Systems » Cylinder Mechanism | Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders | Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon | Schlage Commercial » Key Systems » Keys | Schlage Commercial » Key Systems » Keys » Keys | Schlage Commercial » Key Systems » Keys » Keys » Falcon | Schlage Commercial » Key Systems » Keys » Keys » Schlage
Why does the #2 master pin fall out of a cylinder?
A #2 masterpin can fall out when the key used to operate a cross-keyed cylinder is partially inserted or partially removed prior to completing the key rotation. This issue is typically seen in a...
Schlage Commercial » Key Systems | Schlage Commercial » Key Systems » Cylinders | Schlage Commercial » Key Systems » Cylinders » Cylinder
Does the Schlage B502-191 Schlage cam referenced in the Von Duprin catalog work with Schlage cylinders?
The Schlage B502-191 cam does not work with the Modular Cylinder design (released around 2011.)
The B502-191 should be replaced with either:
L583-474 (1 1/8” cylinder), L583-475 (1 ¼�...
Schlage Commercial » Key Systems » Cylinder Mechanism | Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders | Schlage Commercial » Key Systems » Cylinders » Cylinder
What is the 40-116 cylinder loading tool?
The 40-116 cylinder loading tool was discontinued in 2015....
Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders | Schlage Commercial » Key Systems » Cylinders » Cylinder