What trim may be used with a Von Duprin ESL (Emergency Secure Lockdown) exit device?
Per 2018 IBC 1010.2.8, for locking arrangements in educational occupancies: The door shall be capable of being unlocked from outside the room with a key or other approved means.
An outside night...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can you convert a 360L to an E360L?
No, the electric components may not be field-added to a mechanical trim. A new E360L-BE control must be ordered from the factory....
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin
Do the standard 33/3547A and 98/9947 meet HH (hurricane) standards?
Please specify HH prefix whenever impact-rated hurricane product is required. The factory will then provide the required components which differ from standard device components.
The i...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin
How do I connect External Inhibit wires on Chexit?
Chexit devices shipped prior to 8-24-2015 were solenoid driven: A normally closed card reader contact, key pad contact or any other control contact connects to the Gree...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series
Does EL or QEL conversion kit for Von Duprin exit devices contain mechanism cover plate?
The conversion kit does not contain a new mechanism case cover plate. If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cover p...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Von Duprin
Can the RX feature be added to the 330 or 350 dummy pushbar in the field?
No, the RX can not be added as a retrofit to this product. The standard dummy bar has a rigid push pad. The RX pushbar has an active push pad. A new RX330 or RX350 bar would be required if...
Schlage Commercial » Exit Devices » Touch Bar | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin
Where does the EL dogging rod retaining nut go on the dogging rod?
The retaining nut located under the EL adjustment bushing should be located at the very end of the EL dogging rod...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » System Components » Electrified System Component Accessories » Rectifier » Von Duprin | Schlage Commercial » Von Duprin
Is there a way to make EL devices quieter?
You can't make the EL device quieter. The inrush of current causes the plunger and solenoid to make noise.
A quieter option would be motorized electric latch retraction. Von Duprin h...
Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT | Schlage Commercial » Exit Devices » Touch Bar » 24 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series | Schlage Commercial » Falcon | Schlage Commercial » Von Duprin