Category: Fire Life Safety

(Results from 11 to 20)
Can you order an LCN Closer without a finish?
No, all LCN and Falcon closers are shipped with an approved finish.  ...
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electrohydraulic » 4630 Series | Schlage Commercial » Automatic Operators » Electrohydraulic » 4640 Series | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Senior Swing | Schlage Commercial » Automatic Operators » Pneumatics | Schlage Commercial » Automatic Operators » Pneumatics » 2610 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4810 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4820 Series | Schlage Commercial » Automatic Operators » Pneumatics » 4840 Series | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8200 Series | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » OHC100 Series | Schlage Commercial » Door Controls » Concealed » 3030 Series | Schlage Commercial » Door Controls » Concealed » 3130 Series | Schlage Commercial » Door Controls » Concealed » 330 Series | Schlage Commercial » Door Controls » Concealed » 5030 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series | Schlage Commercial » Door Controls » Fire Life Safety » SEM 1900 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » SEM 7800 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » High Security » 2210 Series | Schlage Commercial » Door Controls » High Security » 4210 Series | Schlage Commercial » Door Controls » High Security » 4510 Series | Schlage Commercial » Door Controls » Overhead Concealed » 5010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 6030 Series | Schlage Commercial » Door Controls » Overhead Concealed » OHC 100 Series | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 1000 Series | Schlage Commercial » Door Controls » Surface Mounted » 1040 Series | Schlage Commercial » Door Controls » Surface Mounted » 1050 Series | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050T Series
How many LCN SEM 24V magnets can be powered by one LCN -3210 Stepdown transformer?
LCN recommends up to 15 SEM units per one LCN transformer. See here for LCN catalog data on SEM units....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » SEM 1900 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » SEM 7800 Series Magnets | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series | Schlage Commercial » LCN | Schlage Commercial
Does an Exterior Exit Door need to be a fire rated opening?
It’s rare to see a fire-rated exterior door, but it can happen.  It’s usually when there is another building nearby – like across a narrow alley.Always check with building codes and local A...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Overhead Concealed » 5010 Series | Schlage Commercial » Door Controls » Overhead Concealed » 6030 Series | Schlage Commercial » Door Controls » Overhead Concealed » OHC 100 Series | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 1000 Series | Schlage Commercial » Door Controls » Surface Mounted » 1040 Series | Schlage Commercial » Door Controls » Surface Mounted » 1050 Series | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4130 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC70 Series | Schlage Commercial » Door Controls » Surface Mounted » SC80 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial » LCN | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050T Series
Will LCN sell internal components of a door closer cylinder?
No....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electrohydraulic | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Pneumatics | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » LCN | Schlage Commercial
What is the current draw on the LCN 4410 HSA closer?
24V AC/DC only (+10%, -15%)Current draw is 120mA...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » LCN | Schlage Commercial
LCN RAL custom powder coat color chart?
See here for the LCN RAL custom powder coat color chart....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Accessories | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » LCN | Schlage Commercial
What is the part number for the arm screw on an LCN manual closer?
Specify LCN Closer series  - 159.This is the screw that attaches the arm to the Closer Body.For example -- If you have a 4040XP closer and need the arm screw.  You would order a 4040XP-159 a...
Schlage Commercial » Automatic Operators | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 1000 Series | Schlage Commercial » Door Controls » Surface Mounted » 1040 Series | Schlage Commercial » Door Controls » Surface Mounted » 1050 Series | Schlage Commercial » Door Controls » Surface Mounted » 1070 Series | Schlage Commercial » Door Controls » Surface Mounted » 1260 Series | Schlage Commercial » Door Controls » Surface Mounted » 1460 Series | Schlage Commercial » Door Controls » Surface Mounted » 4010 Series | Schlage Commercial » Door Controls » Surface Mounted » 4020 Series | Schlage Commercial » Door Controls » Surface Mounted » 4030 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » Door Controls » Surface Mounted » 4110 Series | Schlage Commercial » Door Controls » Surface Mounted » 4000 Series | Schlage Commercial » LCN | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 1250 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450 Series | Schlage Commercial » Door Controls » Surface Mounted » 1450T Series | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series | Schlage Commercial » Door Controls » Surface Mounted » 4050T Series
How many LCN 4310HSA/4410HSA closers can be powered by an LCN step down transformer, -3210?
The LCN -3210 step down transformer can power a maximum of 3 separate 4310/4410HSA closers....
Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN
Can LCN ME/SE closer holders be used on exterior/vestibule doors?
LCN ME/SE closer holders are specifically designed for use on interior fire rated doors. ...
Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series | Schlage Commercial » Door Controls » Fire Life Safety » SEM Series » LCN
Can the 4040SE-3210 transformer be used with both SE and ME 24v units?
Yes, the -3210 transformer is the same transformer thru all the Fire Life and Safety Products (SE and ME).  The current draw rating for the transformer is 400mA which means, it could power...
Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series | Schlage Commercial » Door Controls » Fire Life Safety » SEH Series » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer | Schlage Commercial » Door Controls » Fire Life Safety » Single Point Hold Open Closer » LCN | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series | Schlage Commercial » Door Controls » Fire Life Safety » Fire/Life Safety Series » LCN