When were the benchmark (9130/9140/9150) adapter harnesses -3428-1, -3598, -3430 cables made obsolete?
April 4th of 2008....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark | Schlage Commercial » Automatic Operators » Electromechanical » Benchmark » LCN | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » LCN | Schlage Commercial
What is the current draw on the LCN 4410 HSA closer?
24V AC/DC only (+10%, -15%)Current draw is 120mA...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » Fire Life Safety » Multi Point Hold Open Closer | Schlage Commercial » LCN | Schlage Commercial
LCN RAL custom powder coat color chart?
See here for the LCN RAL custom powder coat color chart....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Fire Life Safety | Schlage Commercial » Door Controls » High Security | Schlage Commercial » Door Controls » Accessories | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » LCN | Schlage Commercial
Where do you find the Falcon 8200 instruction sheets?
See here....
Schlage Commercial » Automatic Operators | Schlage Commercial » Automatic Operators » Electromechanical | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series | Schlage Commercial » Automatic Operators » Electromechanical » 8200 Series » Falcon | Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Automatic Operator | Schlage Commercial » Door Controls » Automatic Operator » 8200 Series | Schlage Commercial
Can the 4040(XP)-384 stop be used in a 4050A Cush arm?
Yes....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » 4040 Series | Schlage Commercial » Door Controls » Surface Mounted » 4040XP Series | Schlage Commercial » LCN | Schlage Commercial | Schlage Commercial » Door Controls » Surface Mounted » 4050 Series
Is there a special template (ST) needed when using a 6030 closer with a Pemko DSH1000 double acting continuous hinge?
ST-3637 – 6030 series closers with DSHP01 double acting continuous hinges.This ST is a templating ST only, it uses all standard parts.ST-3636 - 6030 series closer with DSH1000 double acting continuo...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » LCN | Schlage Commercial
Is there a special template (ST) for a 6030 closer being used with a Pemko DSHP 01?
No ST needed,  just use the standard 6030 instructions/template, locating closer and track from center line of the continuous double swing hinge....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » Door Controls » Concealed » 6030 Series | Schlage Commercial » Door Controls » Concealed » 6030 Series » LCN | Schlage Commercial » LCN | Schlage Commercial
Does LCN offer a 2030 closer less spring tube?
LCN does build a 2030 cylinder with a special end plug and no springs or spring tube for United California Glass & Door only.   If customer needs to replace one of these cylinders they m...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » Door Controls » Concealed | Schlage Commercial » LCN | Schlage Commercial
Are the SC60A-18PA and SC90A-18PA drop plates the same?
Yes, these plates have the same mounting hole dimensions and the cylinders (SC61A, SC93A and SC94A) have the same hole pattern of 3/4" X 9 1/16".Please Note:  The plates are the same but the...
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Surface Mounted | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series | Schlage Commercial » Door Controls » Surface Mounted » SC60 Series » Falcon | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series | Schlage Commercial » Door Controls » Surface Mounted » SC90 Series » Falcon | Schlage Commercial » Falcon | Schlage Commercial
What templating is needed when using a 2030 closer and tectus hinges?
Use the 2030 installation instructions for butt hinges and measure from the apparent centerline of the tectus hinge....
Schlage Commercial » Door Controls | Schlage Commercial » Door Controls » Overhead Concealed | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series | Schlage Commercial » Door Controls » Overhead Concealed » 2030 Series » LCN | Schlage Commercial » LCN | Schlage Commercial