Category: RC-04

(Results from 31 to 40)
What credential formats do Isonas devices (RC04 and IP Bridge**) support?
Isonas Proprietary Prox, Isonas Pure Mobile, Isonas DESFire*** EV2 & EV3 credentials can be read natively.And, with bitmasking, devices can properly support one additional prox credential format; ...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » IPBridge
Can RC04 and Schlage RC be powered via DC instead of PoE?
Yes.  The RC04 and Schlage RC (RC11, RC15, RCK15) can be powered from a 12VDC power source on the ORANGE and BLACK wires.  RC04 power draw is 150 mA or .15 ASchlage RC power draw is 300...
Schlage Commercial » Software » Isonas » RC-04
Is the Isonas RC-04 Compatible with Zentra?
No, the RC-04 is not intended for use with Zentra.  For reader-controllers, the Schlage RC-series (RC11, RC15, RCK15) are recommended.   ...
Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Zentra
How close can the Isonas readers be mounted to another?
We recommend at least 2 to 24" between any Isonas reader and any RF-emitting device.  Mounting them too closely can result in degraded or faulty performance....
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC Reader Controller
Can the Schlage R-1 be installed outdoors?
The RC-04, R-1, and Schlage RC can be mounted outdoors. To prevent water intrusion and humidity/condensation issues we recommend:   1)     Applying dielectric insula...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC Reader Controller
What size Torx Bit is needed for the RC-04?
   If using the supplied torx mounting screw, a T-8 Tamper-Resistent (Pin-In-Torx) bit is needed....
Schlage Commercial » Software » Isonas » RC-04
Why do the options for enrolling credentials at RC-04 doors go away when adding a Schlage reader to the tenant?
Once an Engage device is introduced to the tenant, the credentials must be enrolled at an Engage device, if enrolling by presentation. The system automatically removes the ability to enroll at an Ison...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04
Why are there approvals being shown in the history, but no one is at the door?
Often, this is caused when a reader has been offline and comes back online after people have come in and out of the door. The RC-04 will store the information of the users coming in and out and once t...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04
My Isonas device (RC03, RC04, IP Bridge) is showing as not connected in my Pure Access Cloud tenant.
Disconnected readers will continue to function in an offline state so long as they are powered up.  Their function will be based upon the information in the last compile that they completed while...
Schlage Commercial » Software » Isonas | Schlage Commercial » Software » Isonas » RC-04 | Schlage Commercial » Software » Isonas » RC-03 | Schlage Commercial » Software » Isonas » IPBridge
What is the difference between the "REX" and "REX w/o Unlatch" settings for an Isonas RC04?
When set to "REX" a trigger on the REX input will result in a "REX Admit" history event and it will trigger the output to unlatch for the set latch interval period.When set to "REX w/o Unlatch" a trig...
Schlage Commercial » Software » Isonas » Pure Access Cloud | Schlage Commercial » Software » Isonas » RC-04