Can we print on Schlage access cards?
Yes, you can on any of our cards, however, it depends on printer settings with heat, they usually cannot print on a clamshell.They can on the ISO (International Organization for Standardization) card....
Schlage Commercial » Credentials
What Facility code is used on a 32X bit
No facility code is used with this format. ...
Schlage Commercial » Credentials
When using the 9520 credential, how many door will it accept using no tour?
The memory on the card can only hold 4 door using the no tour option....
Schlage Commercial » Credentials
What is needed to reorder construction cards for an existing site?
Card part number 9651 Bit Format: 48X Site/Facility code: (use same site/facility code generated for original order of fobs) City Code: (use same city code as origi...
Schlage Commercial » Credentials
How are the secure keys and formats in smart cards handled?
 When it comes to secure keys and formats, you can look at it like this: The customer, owns that config, we just have permission to use it.  They have to authorize people to use their cards ...
Schlage Commercial » Credentials
Will the APTIQ 4KBYTE/32K Bit keyfobs (8640) will work with a MT15 reader, is there something in programming that has to be turned on to use this fob?
Any of our Aptiq fobs will work with our MT reader by default, however, there is an issue with the EV1 fobs in particular, they are having trouble being read. We're actually suggesting not using EV1 a...
Schlage Commercial » Credentials
Will Allegion MT readers read HID prox?
They will read HID prox up to 37-bits and iClass CSN.  If you have a 48-bit Corporate 1000 Prox this is proprietary to HID and will not work on our readers. We now have new Si readers avail...
Schlage Commercial » Credentials | Schlage Commercial » Readers
Is the 37X Allegion format similar to the Hid H10304 format?
Yes, it 37X is same as H10304 HID...
Schlage Commercial » Credentials
How do you order/read an order for contsruction fobs for the Control lock?
Example order info looks like this:Credentials.9651.CT8X4248.48x.963.100.100.1.10.01-Standard Default.No6….Here is the breakup:Credentials.Part#. CardTrax Account#.Bit Format. FC. Internal Start#.Ex...
Schlage Commercial » Credentials | Schlage Commercial » Credentials » Smart Card
How can I find the facility code on an existing credential?
There is a long stamped number on the fob.  If you can email us or call us with the long stamped number, we can look it up for you. Email:  electronic_lock_techprodsupport@allegio...