What is a Hospital Stop?
Hospital Stops are located at the bottom of the frame jambs and/or mullions. The integral door stops are terminates above floor line and is closed with a 45° or 90° angle to facilitate cleaning at t...
Doors and Frames » Frames » DW & K Series » Steelcraft | Doors and Frames » Frames » F & FN Series » Steelcraft | Doors and Frames » Frames » FE & DE Series » Steelcraft | Doors and Frames » Frames » MU Series » Steelcraft | Steelcraft
Does Steelcraft have frame installation instructions?
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop Manu...
Doors and Frames » Frames » DW & K Series » Steelcraft | Doors and Frames » Frames » F & FN Series » Steelcraft | Doors and Frames » Frames » MU Series » Steelcraft | Doors and Frames » Parts » Small Parts » Steelcraft | Steelcraft
What power supply is needed for EL devices?
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the 16...
Power Supplies » Standard » PS900 Series » Von Duprin
What are the amperage and power supply requirements for the Von Duprin Chexit (CX) devices?
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gauge ...
Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Power Supplies » Standard » PS900 Series » Von Duprin
What are the keyway types and patents?
HIGH SECURITY Primus/Primus XP: In addition to six cuts for standard locking mechanism, there are five side finger pins to operate the secondary sidebar lock. Primus keys will operate non-Primus...
Key Systems » Cylinder Mechanism » Schlage | Key Systems » Keys » Keys » Schlage
What maintenance is required for an LCN closer?
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments.  Monthly, quarterly, and annual visual inspections are recommended for Fire/Lif...
Automatic Operators » Electrohydraulic » 4630 Series » LCN | Automatic Operators » Pneumatics » 2610 Series » LCN | Automatic Operators » Pneumatics » 4810 Series » LCN | Door Controls » Overhead Concealed » 2010 Series » LCN | Door Controls » Overhead Concealed » 2030 Series » LCN | Door Controls » Concealed » 3030 Series » LCN | Door Controls » Concealed » 3130 Series » LCN | Door Controls » Concealed » 330 Series » LCN | Door Controls » Concealed » 5030 Series » LCN | Door Controls » Concealed » 6030 Series » LCN | Door Controls » High Security » 2210 Series » LCN | Door Controls » High Security » 4210 Series » LCN | Door Controls » High Security » 4510 Series » LCN | Door Controls » Surface Mounted » 1070 Series » LCN | Door Controls » Surface Mounted » 1460 Series » LCN | Door Controls » Surface Mounted » 4010 Series » LCN | Door Controls » Surface Mounted » 4020 Series » LCN | Door Controls » Surface Mounted » 4030 Series » LCN | Door Controls » Surface Mounted » 4040 Series » LCN | Door Controls » Surface Mounted » 4110 Series » LCN | Door Controls » Surface Mounted » 4130 Series » LCN | Door Controls » Surface Mounted » 4000 Series » LCN | LCN
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop....
Mechanical Accessories » Holders and Stops » 410 Series » Glynn-Johnson | Door Controls » Surface Mounted » 4040 Series » LCN
What is the best way to test the Von Duprin EL solenoid?
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green wi...
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Von Duprin
What special template (ST) is used with a 4110 closer and GJ90 series?
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 ...
Mechanical Accessories » Holders and Stops » 90 Series » Glynn-Johnson | Door Controls » Surface Mounted » 4110 Series » LCN
What is the rough opening in walls for frame installations?
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Wall...
Doors and Frames » Frames » DW & K Series » Steelcraft | Doors and Frames » Frames » F & FN Series » Steelcraft | Doors and Frames » Frames » FE & DE Series » Steelcraft | Doors and Frames » Frames » MU Series » Steelcraft | Steelcraft