What power supply is needed for EL devices?
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from po...
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
What replaces the Von Duprin PS873 Power Supply
The PS900 series of power suppllies replace the PS873Only the PS900 series is UL294 compliant. PS873 is not UL294 compliant. ...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » Von Duprin
Why does an EL1790 retract but can be bounced out of electric retraction?
Check for correct power supply, PS873-2/4TD or PS914-2RS/4RL, and verify the wire gauge from power supply to the EL1790 device either 14 or 12 gauge....
Schlage Commercial » Exit Devices » Touch Bar » 1790 Series » Falcon | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
What replaces the Von Duprin PS873 power supply?
  Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
Where is the cross reference list for PS800 to PS900 series power supplies?
Von Duprin PS914-4RL power supply replaces the PS873-4TD....
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
Are the legacy Von Duprin PS873 and the current PS900 power supplies filtered and regulated?
The Von Duprin PS873 and PS900 series power supplies are filtered and regulated....
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
Customer has existing EL99 x CM993HW x PS873-2, They now want to add a pushbutton to allow entry from outside. How does it get wired?
Push button gets connected to the input of the PS873-2 power supply (SC & I1)....
Schlage Commercial » Electronic Locks » Offline » CM Series » Schlage Electronics | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
What power supply is used to operate the Von Duprin E 996 L trim?
The Von Duprin E996L trim required .22 amps at 24VDC....
Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » Von Duprin
What would cause an EL device to pull and release?
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will reso...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin
What is the maximum distance I can have from VD EL to PS873-2?
Maximum distance is 200' with #12 gauge wire with VD EPT2/10...