What is an interconnected lock?
Interconnected Locks: a lockset whose trim provides a means of simultaneous retraction of two or more bolts which may also be operated independently Medium duty Commercial, government or multi-fam...
Mechanical Locks » Tubular / Interconnected » CS200 Series » Schlage | Mechanical Locks » Tubular / Interconnected » H Series » Falcon | Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Mechanical Locks » Tubular / Interconnected » S200 Series » Schlage | Schlage
What are the current and voltage requirements of the 10-042 strike?
 The 10-042 is an electric strike used for cylindrical and tubular latch sets.    VOLTAGE  24 VAC  12 VDC  ...
Mechanical Locks » Cylindrical » A Series » Schlage | Mechanical Locks » Cylindrical » AL Series » Schlage | Mechanical Locks » Cylindrical » D Series » Schlage | Mechanical Locks » Cylindrical » ND Series » Schlage | Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Mechanical Locks » Tubular / Interconnected » S-Series » Schlage
Are parts still available for the Schlage interconnect G series lock?
The G-Series lockset was discontinued in 1981, and all service parts for the G-Series lock were discontinued in 1985.  The current interconnect lock, S200 series (available in levers only), ...
Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Schlage
What size is the Schlage H escutcheon?
  Schlage H-Series Escutcheons    Part Number  Description Dimension   07-057  Inside escutcheon and turn  6.92" x 2.75"  07-035  Inside escutcheon, dummy - H170  ...
Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Schlage
Are the Schlage H series knobs sold separate?
The knobs are available, part numbers listed below. 01-008 for a closed knob 01-009 for open levers 01-018 for cylinder knobs, LEV lever design not available in 01-018 01-026 for FSIC Specify ...
Mechanical Locks » Tubular / Interconnected » H Series » Schlage
What does the H-Series housing and linkage look like?
The housing and linkage is what sits underneath the inside escutcheon plate and can be seen in this exploded view.  The linkage is what gives the H lock simultaneous retraction.  It allows the deadb...
Mechanical Locks » Tubular / Interconnected » H Series » Schlage
How do I specify temporary construction cores?
Use the cylinder suffix 'T' for full size interchangeable core or the cylinder suffix 'HD' for small format interchangeable core, see Figure 1.  Small format also has a disposable core option whi...
Mechanical Locks » Cylindrical » A Series » Schlage | Mechanical Locks » Cylindrical » AL Series » Schlage | Mechanical Locks » Cylindrical » D Series » Schlage | Mechanical Locks » Cylindrical » ND Series » Schlage | Mechanical Locks » Deadbolts » B Series » Schlage | Mechanical Locks » Mortised » L400 Series » Schlage | Mechanical Locks » Mortised » L9000 Series » Schlage | Mechanical Locks » Mortised » LV9000-Series » Schlage | Mechanical Locks » Portable » CL Series » Schlage | Mechanical Locks » Portable » Padlocks » Schlage | Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Mechanical Locks » Tubular / Interconnected » S200 Series » Schlage | Mechanical Locks » Tubular / Interconnected » S-Series » Schlage
What is the grading for S200 and H series locks?
Neither lock has a BHMA grade....
Mechanical Locks » Tubular / Interconnected » H Series » Schlage | Mechanical Locks » Tubular / Interconnected » S200 Series » Schlage
Are the H locks available in SFIC?
The H-Series is not available with a small format interchangeable core option....
Mechanical Locks » Tubular / Interconnected » H Series » Schlage
What is the distance between the two main prep holes on the H lock from Schlage?
The center to center distance is 4 inches....
Mechanical Locks » Tubular / Interconnected » H Series » Schlage