Explain the function of the D271.
The D271 is a deadbolt with a thumbturn on the inside and an occupancy indicator on the outside. When the bolt is thrown, the indicator reads 'In Use", when the deadbolt is retracted, the indicator re...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
What replaced the D871 deadbolt?
The Falcon D400 and D800 series (including the D871) were discontinued in 2008....
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
Is there a spacer for the Schlage B500 or Falcon D200 deadbolts for use on a 1 3/8" door?
Schlage B500 The B500 series non-IC will fit onto a 1 3/8" thick door out of the box with no additional parts. The B500 IC option (B, BDC, GD, HD) requires a shim kit, 36-071 ...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
How does a classroom deadbolt lock operate?
Classroom Deadbolt Lock (ANSI Function: E0171 for B663/763/863 and D111, E0172 for B563 and D211 )Deadbolt thrown or retracted by key outside. Inside turn unit will retract bolt only. Bolt automa...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon) | Schlage Commercial » Mechanical Locks » Deadbolts » B Series (Schlage)
What replaced the D400 series or the D800 series?
  Part compatibility (Old vs new): With the exception of the cylinder, most of the parts are neither backward nor forward compatible.  This includes the deadbolt. The cylinder...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
Installation instructions for the D251 thumbturn x thumbturn deadbolt.
D251 Installation Instructions...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
How to remove a double cylinder deadbolt?
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructions ...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon) | Schlage Commercial » Mechanical Locks » Deadbolts » B Series (Schlage)
Are the D100 and D200-Series thumbturns ADA compliant?
The D100-Series and D200-Series have ADA compliant thumbturns. See the Falcon D series Brochure on page 2 stating ADA compliance....
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)
How do I order a lock for a non-standard or thick door?
Most locks will have a standard door range they will install on, but occasionally customers will want to use them on thicker doors.  In order to do so, the extended door thicknes...
Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon) | Schlage Commercial » Mechanical Locks » Deadbolts » B Series (Schlage) | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series
Are 7-pin conventional cylinders available with Falcon double cylinder deadbolts?
Due to space constraints, Falcon double cylinder deadbolts (D131 and D231 functions) are not available with 7-pin conventional cylinders (P7 suffix).   All other Falcon keyed deadbolts (D111...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon)