Category: D Series

(Results from 11 to 20)
Can the UL Listed Falcon D100 and D200 deadbolts use a 1 1/2" hole door prep?
The door prep hole for the UL listed Falcon deadbolts needs to be 2 1/8".  The fire cup will not fit in a 1 1/2" hole door prep.  ...
Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon
How do the emergency keys operate the B571 and D271 indicator deadbolts?
On the B571 and D271, the emergency keys (61-509 and 61-510) can only be inserted/retracted when the bolt is thrown.  The procedure is as follows:insert emergency key into locked deadboltturn key...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage
What is the part number for the blank plate for D261M and B581?
The part number for a blank mounting plate for the D261M and B581 is 38-034....
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage | Schlage Commercial
Will a Falcon D100 deadbolt with IC core fit on a 1 3/8" door?
The standard door range for the Falcon D100 and D200 series deadbolts with IC core is 1 5/8"  - 2 1/4".  Both lock series can be ordered for 1 3/8" thick doors by specifying DT 1 3/8" T...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series
What is the Minimal Stile requirements for Falcon Locksets?
...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series (Falcon) | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What is a Grade 2 Lock?
Grade 2 locks are tested and certified to be in compliance with the following ANSI/BHMA Standards: Cylindrical, Bored and Preassembled Locks & Latches 400,000 Certified Cycles ANSI/BH...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series (Falcon) | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Cylindrical » A Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » AL Series - Discontinued | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » CS200 Series | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » H Series - Discontinued | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » Y Series - Discontinued | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » S200 Series - Discontinued | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » S-Series
Are drive in latches designed to be used in wood doors only?
Schlage and Falcon drive in latches are designed to be used in wood doors ONLY. A hollow metal door does not provide sufficient support for a drive in latch. ...
Schlage Commercial » Mechanical Locks » Cylindrical » A Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » AL Series - Discontinued | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Cylindrical » ALX Series
What does the cylinder suffix BDC mean?
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use....
Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Mechanical Locks » Cylindrical » B Series (Falcon) | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » AL Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L400 Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » H Series - Discontinued | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » Y Series - Discontinued
What is a Grade 1 Lock?
Grade 1 locks are tested and certified to be in compliance with the following ANSI/BHMA Standards:   Cylindrical, Bored and Preassembled Locks & Latches   800,...
Schlage Commercial » Mechanical Locks » Cylindrical » RU Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » D Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series | Schlage Commercial » Mechanical Locks » Mortised » LV9000-Series
What is the door range for the Falcon D271?
The tailpiece (B520-653) is the same for all door thicknesses between 1-3/8" up to 2-¼".The mounting screws are different for a door range greater than 1-¾". The mounting screw part number is B520-6...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series