Can the UL Listed Falcon D100 and D200 deadbolts use a 1 1/2" hole door prep?
The door prep hole for the UL listed Falcon deadbolts needs to be 2 1/8". The fire cup will not fit in a 1 1/2" hole door prep. ...
Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon
How do the emergency keys operate the B571 and D271 indicator deadbolts?
On the B571 and D271, the emergency keys (61-509 and 61-510) can only be inserted/retracted when the bolt is thrown. The procedure is as follows:insert emergency key into locked deadboltturn key...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage
What is the part number for the blank plate for D261M and B581?
The part number for a blank mounting plate for the D261M and B581 is 38-034....
Schlage Commercial » Mechanical Locks | Schlage Commercial » Mechanical Locks » Deadbolts | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage | Schlage Commercial
Will a Falcon D100 deadbolt with IC core fit on a 1 3/8" door?
The standard door range for the Falcon D100 and D200 series deadbolts with IC core is 1 5/8" - 2 1/4". Both lock series can be ordered for 1 3/8" thick doors by specifying DT 1 3/8" T...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series
Will the Schlage L9000 Mechanical Locks ordered with RX, LX , DPS or DM Options include the Molex Connector?
The L9000 Mechanical Locks will include the Molex Connector when ordered with RX, LX, DPS or DM Options.
...
Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage » Schlage | Schlage Commercial » Mechanical Locks » Mortised | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series
What is the minimum stile width for Falcon locks?
The minimum stile for each lock will depend on the backset and Rose diameter/Escutcheon width. See the Falcon Minimum Stile Requirements for the minimum stile for each lock series and backsets av...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series | Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued | Schlage Commercial » Mechanical Locks » Deadbolts » D Series | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Tubular / Interconnected » H2 Series