What is the maximum wire run length for T881 and T851?
For the T881 and T851 wire run lengths. You can reference the chart for the ND series here....
Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon
Do Schlage or Falcon mechanical locks carry the American Iron and Steel certification?
Schlage and Falcon mechanical locks do not carry the American Iron and Steel (AIS) certification. American Iron and Steel Act (AIS) The only product that Allegion can provide AIS documentation f...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » W Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series » Schlage | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series | Schlage Commercial » Mechanical Locks » Cylindrical » ALX Series
What is needed to convert a Falcon T series from KIL to FSIC?
To convert a Falcon T series from FSIC to SFIC you will need to replace: Spring cage spindle -requires disassembly of the spring cage Lever Driver/tailpiece ...
Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon
Where can I find weight and measurements for Schlage products?
Click here for the Weight and measurements PDF for Schlage. Click here for the Weight and measurements PDF for Falcon. click here for the Weight and measurements PDF for Steel...
Schlage Commercial » Key Systems » Cylinders » Cylinder | Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » B Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » W Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » A Series - Discontinued | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » MA-Series » Falcon | Schlage Commercial » Mechanical Locks » Mortised » L400 Series | Schlage Commercial » Mechanical Locks » Mortised » L400 Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » LM9300 Series » Schlage | Schlage Commercial » Falcon | Schlage Commercial » Mechanical Locks » Mortised » LM9200 | Schlage Commercial | Schlage Commercial » Dexter | Schlage Commercial » Mechanical Locks » Cylindrical » ALX Series
What do the letters and numbers mean in a Falcon lock part number?
Falcon Series locks are available with a number of functions, cylinder options, lever/knob styles, latch, strike and finish options. The Falcon Locks Catalog can be helpful in determining what options...
Schlage Commercial » Mechanical Locks » Cylindrical | Schlage Commercial » Mechanical Locks » Cylindrical » B Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » RU Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » W Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » K Series - Discontinued
Is the 031416-000 solenoid and 030716-001 clutch driver still offered?
As of March 2022 the T851 solenoid 031416-000, and T851 clutch driver 030716-001 are no longer offered and would need to be replaced with the 031516-000 solenoid and the clutch driver 24368706 663.&nb...
Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon
What is the tailpiece orientation for the Falcon T series using conventional cylinders?
For proper function of the lock, the right tailpiece must be used and installed correctly. All T-locks with standard cylinders must have the tailpiece installed VERTICALLY.  Please click he...
Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon | Schlage Commercial » Falcon
Is the Falcon T series windstorm rated?
The T Series is only Hurricane rated, not rated for Tornado....
Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon
Does the IC lever for the Falcon T series have a hole for the lever catch?
There is no lever catch hole on any T series prepped for IC cores whether it is SFIC or IC competitor prep. To remove the lever on a T series Falcon lock with IC lever prep, you will have t...
Schlage Commercial » Mechanical Locks » Cylindrical » T Series | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon
How many cores are included on double cylinder functions ordered with construction cores?
When a double cylinder function lock is specified with IC construction cores, two cylinders will be sent for both the inside and outside....
Schlage Commercial » Key Systems » Cylinder Mechanism » Schlage | Schlage Commercial » Key Systems » Cylinders » Cylinder » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » T Series » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » X Series - Discontinued » Falcon | Schlage Commercial » Mechanical Locks » Cylindrical » ND Series » Schlage | Schlage Commercial » Mechanical Locks » Deadbolts » D Series » Falcon | Schlage Commercial » Mechanical Locks » Deadbolts » B Series » Schlage | Schlage Commercial » Mechanical Locks » Mortised » MA-Series » Falcon | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series » Schlage | Schlage Commercial » Mechanical Locks » Cylindrical » ALX Series | Schlage Commercial » Mechanical Locks » Cylindrical » TM Series