Is the Von Duprin Guard X 2670 device hurricane rated (HH)?
The HH2670 is only approved for use on single flush doors per NOA 15-0826.23 and FBC FL#12400.3.  It is shown using the 267 strike and has a design pressure rating of +/-55 PSF. ...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » Guard X | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Does 230DT through-bolt to the 2670 Guard X?
No.  This trim is not intended to be thru bolted to the Guard-X device which is why  you need the special screw pack 050140.  The trim is  mounted independent of the device....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Can the 2670 Guard-X printing be rotated?
Yes.  Take off the center case cover. Slide the signage out of the push pad by pushing it either left or right. Flip over the signage and reinstall.  ...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What is the difference between the M996L and E996L?
The E996L uses a solenoid. It is field selectable for fail safe or fail secure operation. It is only available with a24VDC solenoid. The M996L uses a motor. It is field selectable for fail safe or fai...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin | Schlage Commercial » System Components » Electrified System Component Accessories » Rectifier » Von Duprin
Must the tailpiece extension always be used when installing a cylinder on the Guard-X 2670 device?
The tailpiece extension should only be used when the cylinder tailpiece is recessed less than 3/4" inside the cylinder bracket. ...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What is the purpose of the pan head screw on the back of the 2670 Guard-X device chassis?
This screw sits next to the cylinder input cam and it keeps the pull side cylinder cam from rotating.  If a cylinder will not be used for the pull side, the screw should remain installed. ...
Schlage Commercial » Exit Devices » Touch Bar » Guard X | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
If I am using the PT790 transformer to power the Guard-X 2670, is it required to install the 9V battery?
The battery does not have to be installed in order for the transformer to work; but if the battery is installed, it will serve as power backup if AC power is lost....
Schlage Commercial » Exit Devices » Touch Bar » Guard X | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
On the PT790 transformer cable, which way do I install it to the circuit board? Which wire is Ground?
As of April 2017, the red wire is Ground. When installing the connector to the Guard-X 2670 circuit board, the red wire should face toward the circuit board....