Is the Von Duprin Guard X 2670 device hurricane rated (HH)?
The HH2670 is only approved for
use on single flush doors per NOA 15-0826.23 and FBC FL#12400.3. It is
shown using the 267 strike and has a design pressure rating of +/-55 PSF.
...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » Guard X | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Does 230DT through-bolt to the 2670 Guard X?
No. This trim is not intended to be thru bolted to the Guard-X device which is why you need the special screw pack 050140. The trim is mounted independent of the device....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Can the 2670 Guard-X printing be rotated?
Yes.
Take off the center case cover. Slide the signage out of the push pad by pushing it either left or right. Flip over the signage and reinstall.
...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What is the difference between the M996L and E996L?
The E996L uses a solenoid. It is field selectable for fail safe or fail secure operation. It is only available with a24VDC solenoid.
The M996L uses a motor. It is field selectable for fail safe or fai...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin | Schlage Commercial » System Components » Electrified System Component Accessories » Rectifier » Von Duprin