What is the part number for the 2670 metal tailpiece extension?
The part number for 2670 cylinder tail piece extension is 050379....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin | Schlage Commercial » Von Duprin
Why would 2670 have a faint alarm?
The battery may be weak or possibly the board is bad....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Is there an electric strike that will work with the 2670 Guard X?
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Can the 2670 be cut down to fit smaller door widths?
The 2670 Guard X device can't be cut down to fit doors less than 3 feet.  This device is designed to fit doors 36"-48" door width....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Parts manuals for Von Duprin exits?
Von Duprin parts manuals are downloadable on the US.Allegion.com document library page.In the filter, select:Document Type: ManualBrand: Von DuprinCategory: Exit DevicesThis will provi...
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Mechanical Accessories » Mullion » Von Duprin | Schlage Commercial » Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » Von Duprin
Is the piezo alarm (horn) available as a separate part for the Guard X?
The piezo horn is part of the circuit board and is not available by itself. You must replace the circuit board, part number PCB.10018...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Is the Guard X 2670 approved for exterior use?
The Guard X device has been approved for exterior use applications....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Is the Von Duprin Guard-X exit device fire rated?
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. ...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin | Schlage Commercial » Von Duprin
Why does a 2670 Guard X not extend the bolt when I turn the key?
If the tailpiece of the rim cylinder is not engaging into the 2670 guard X cam because the tailpiece is too short and they are not using the tailpiece extension that is provided with the Guard X devic...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Can a 2670 Guard-X device be cut down in the field?
The 2670 Guard-X device cannot be cut down in the field....