What strike is required when using the 2670 Guard-X on a pair of doors?
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike ...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Is there a pull side trim that mounts back to back with the Von Duprin Guard X alarm lock?
There is no pull that mounts back to back on the Guard X, the pull needs to be mounted above or below the Guard X device....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What is the part number for the pcb board on the 2670 Guard X exit device?
The following are part numbers for 2670 Guard X exit device PCB: pcb.10018 for English pcb.10019 for Spanish pcb.10020 for French...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What exit device is weather rated?
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. The...
Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Is the 2670 Guard X fire rated?
The Von Duprin 2670 Guard X is used only on non fire rated doors thus is not fire rated....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
How to replace the circuit board or horn on a Guard-X device?
See PCB replacement instructions below. The horn is part of the board and can only be replaced by replacing the entire board....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
After replacing the battery on a Von Duprin 2670 Guard X why would the horn stop working?
Replacing the battery on the 2670 should not cause the unit stop working. Make sure the spring that provides tension on the plastic finger is not bent out. The spring should be at a 90 degrees be...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
What mullion is suggest for use with a 2670 double door application?
Should use the 4954 or 4954 blank mullion....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Can you hardwire a 2670 and not use the PT-790?
The PT-790 is the pluggable power supply and is required if you want to hardwire the 2670 Guard X....
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin
Does Von Duprin offer any pulls that through bolt to the Guard-X device?
Von Duprin does not offer any lever trim or pulls that through bolt to the Guard X device.  Ives has the 8102-6 and 8105-6 pulls that can be lined up with the mounting screws of the exit device but...
Schlage Commercial » Exit Devices » Touch Bar » Guard X » Von Duprin