Can the 9475 be used on a pair of doors with the 9447?
The 9475 mortise device is for single door only. ...
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
What is the difference between normally open and normally closed?
In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by oper...
Exit Devices » Cross Bar » 55 Series » Von Duprin | Exit Devices » Cross Bar » 88 Series » Von Duprin | Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 19 Series » Falcon | Exit Devices » Touch Bar » 24 Series » Falcon | Exit Devices » Touch Bar » 25 Series » Falcon | Exit Devices » Touch Bar » 22 Series » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Mechanical Locks » Cylindrical » ND Series » Schlage | Mechanical Locks » Mortised » L9000 Series » Schlage | Von Duprin
Does the Inpact EL94/95 have the same solenoid as the EL devices?
The EL94/95 Inpact solenoid is different than the EL33A/35A/98/99 solenoid. The part for the Inpact solenoid is 113189.  As of 1/16/2013, the 113189-00 EL INPACT SOLENOID/PLUNGER ASSY is no longe...
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
What Von Duprin device works with a Kaba Ilco LP1000?
 We do not do testing on other manufacturer's trims to work with Von Duprin exit devices.  You will need to contact Kaba Ilco....
Exit Devices » Cross Bar » 55 Series » Von Duprin | Exit Devices » Cross Bar » 88 Series » Von Duprin | Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 22 Series » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can you have a 94/95 device with a QEL option?
As of 1/15/2012 the 94/95 device is available with a QEL electric latch retraction option. See attached bulletin....
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
Can the 94/9547 have the RX option?
The RX request exit switch is not available with 94/95 exit devices....
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin
How many wires does the Von Duprin E7500 lock body have and how are they used.
The Von Duprin E7500 has a total of 8 wires. Two power wires. 12VDC solenoid has yellow wires. 24VDC solenoid has black wires. Six switch wires. Latchbolt monitor switch has three wires, Re...
Exit Devices » Cross Bar » 55 Series » Von Duprin | Exit Devices » Cross Bar » 88 Series » Von Duprin | Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Can dogging be added to a Von Duprin fire rated exit device?
No, dogging cannot be added to a fire-rated mechanical exit device. Fire rated devices can be only electronically dogged and drop during fire activation....
Exit Devices » Cross Bar » XX Series » Falcon | Exit Devices » Cross Bar » 55 Series » Von Duprin | Exit Devices » Cross Bar » 88 Series » Von Duprin | Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 19 Series » Falcon | Exit Devices » Touch Bar » 24 Series » Falcon | Exit Devices » Touch Bar » 25 Series » Falcon | Exit Devices » Touch Bar » 22 Series » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Why do you need the potted circuit breaker for the Von Duprin EL device?
The potted circuit breaker for the Von Duprin EL device does the switching from the 16 amp pull coil on the solenoid to the .33 amp holding coil of the solenoid....
Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin
Does the wire size of an EPT affect the operation of an EL device?
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
Exit Devices » Recessed » 2390 Series » Falcon | Exit Devices » Recessed » 94/95 Series INPACT » Von Duprin | Exit Devices » Touch Bar » 1490 Series » Falcon | Exit Devices » Touch Bar » 1590 Series » Falcon | Exit Devices » Touch Bar » 1690 Series » Falcon | Exit Devices » Touch Bar » 1790 Series » Falcon | Exit Devices » Touch Bar » 24 Series » Falcon | Exit Devices » Touch Bar » 25 Series » Falcon | Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Exit Devices » Touch Bar » 98/99 Series » Von Duprin | System Components » Power Supplies » EPT Series » Von Duprin