How do I communicate with a PED-500 (KC-2) Deadbolt lock using the HHD?
When using the SUS and HHD to program the PED-500 deadbolts, please be aware of the following:The PED-500 will only communicate to the SUS if the red programming key has been presented and the unit is...
Schlage Commercial » Electronic Locks » Hand Held Devices » HHD » Schlage Electronics | Schlage Commercial » Electronic Locks » Offline » Multi-Family | Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
How do I create a programming fob for the BE367?
Remove 9v battery, press and hold down Schlage button while replacing battery, hold till lock beeps, present red programming fob...
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
What is the difference between programming a CT1000 and a CT5000 in Schlage Express?
In Schlage Express, Under Doors setup and configuration, the door Type for the old CT1000 was programmed as a CM/KC-2 lock supporting 1000 credentials maximum. The in newer Schlage Express version 4.x...
Schlage Commercial » Electronic Locks » Offline » Multi-Family | Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics | Schlage Commercial » Electronic Locks » Standalone/Offline | Schlage Commercial » Software » Schlage Express » Software » Schlage Electronics
PED-500 First Time Programming Credential enrollment
A PED-500 (also known as a BE367 or FE210)  that is currently at Factory Defaults (or just out of the box) will require the bolt to be retracted in order for the deadbolt to accept the Programmin...
Schlage Commercial » Electronic Locks » Offline » Multi-Family | Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
What is the Low Battery level for the BE367 and the FE210?
Low Battery indication occurs when the battery is depleted to 6.5 volts. Critical Battery indication occurs at 6.0 volts....
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
How many operations will the BE367 or FE210 perform after reaching Low Battery level?
When the battery is depleted to 6.5 volts (i.e., the Low Battery Nuisance Delay begins), a valid Normal credential will operate the lock at least 500 times before Critical Battery Level lockout occurs...
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
Do I have to reprogram the BE367 or FE210 if the battery dies completely?
No, the programming information (door name, users, access rights, etc.) is stored in nonvolatile memory and is not lost if the battery dies....
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
Do I have to re-enroll the Programming Credential if the BE367 or FE210 battery dies completely?
No, the Programming Credential data is not lost if the battery dies....
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
Do the BE367 and FE210 retain audit data if the battery dies completely?
Audit data is stored in nonvolatile memory, so it is not lost if the battery dies....
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics
How do Construction Credentials work on the BE367 and the FE210?
When a Construction credential is presented to a lock in Factory Default condition, the outside thumb turn will engage and the green LED will flash for the default thumb turn actuation period. Access ...
Schlage Commercial » Electronic Locks » Offline » Multi-Family » Schlage Electronics